When a solenoid is first energized, its coil receives a pulse of high inrush current that decreases as the plunger closes. If the plunger does not close, the high inrush current continues, which can cause the coil to overheat and burn out. This is the most common cause of solenoid failure and spotting it is easy.Apr 8, 2013