1 Channels 1mA per Channel 1pA 70 dB Instrumentational OP Amps 5V 2V~10V ±1V~5V 8-DIP (0.300, 7.62mm)
SOT-23
ALD1701APAL Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
8 Weeks
Mount
Through Hole
Mounting Type
Through Hole
Package / Case
8-DIP (0.300, 7.62mm)
Number of Pins
8
Supplier Device Package
8-PDIP
Operating Temperature
0°C~70°C
Packaging
Tube
Published
2012
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Max Operating Temperature
70°C
Min Operating Temperature
0°C
Output Type
Rail-to-Rail
Operating Supply Voltage
5V
Number of Channels
1
Number of Circuits
1
Operating Supply Current
120μA
Nominal Supply Current
250μA
Output Current
1mA
Current - Supply
120μA
Slew Rate
1V/μs
Amplifier Type
General Purpose
Common Mode Rejection Ratio
70 dB
Current - Input Bias
1pA
Voltage - Supply, Single/Dual (±)
2V~10V ±1V~5V
Output Current per Channel
1mA
Input Offset Voltage (Vos)
900μV
Gain Bandwidth Product
700kHz
Voltage Gain
107.96dB
Voltage - Input Offset
900μV
Current - Output / Channel
1mA
Max Dual Supply Voltage
6V
Min Dual Supply Voltage
1V
RoHS Status
ROHS3 Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
50
$6.37560
$318.78
ALD1701APAL Product Details
ALD1701APAL Overview
In order to protect the op amps, a 8-DIP (0.300, 7.62mm) case is used. The instrumentation amplifier in this picture is of the General Purpose-type. The case in which buffer amplifier is delivered is called a Tube case. It has 8 pins that make up the linear amplifier. Regarding input offset voltage, buffer amplifier rates 900μV voltage. It is recommended that this electronic component be mounted using the Through Hole mounting type. Regarding the operating temperature of this device, instrumentation amplifier performs well at a temperature of 0°C~70°C . In order for this instrumentation amplifier to operate, the supply current needs to be between 120μA and 10 . There should be no change in the voltage gain. A linear amplifier like this has 1 circuits on it. Op amp ic has 1 channels. One of its many advantages is that buffer op amp outputs Rail-to-Rail signals. Using this buffer op amp requires a temperature of at least 0°C. You should only use op amp buffer at temperatures that are no higher than 70°C. The operating supply voltage of instrumentation amplifier is rated 5V voltage. It is recommended that this electronic component be used with an 120μA supply. As a general rule, you should conduct this electronic component under dual supply voltages of 6V volts.
ALD1701APAL Features
107.96dB voltage gain Output Type: Rail-to-Rail
ALD1701APAL Applications
There are a lot of Advanced Linear Devices Inc. ALD1701APAL Instrumentational OP Amps applications.