Hall Effect, Open Loop Sensor 1-Channel Bidirectional -20°C~85°C 5V DC~50kHz 100A Accuracy-±1% Linearity-±4.4%
SOT-23
ACS752SCA-100 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Mount
Through Hole
Mounting Type
Through Hole
Package / Case
5-CA Formed Leads
Number of Pins
5
Operating Temperature
-20°C~85°C
Packaging
Tube
Published
2005
JESD-609 Code
e3
Part Status
Obsolete
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Number of Terminations
5
Terminal Finish
MATTE TIN
Technology
BICMOS
Voltage - Supply
5V
Terminal Position
UNSPECIFIED
Terminal Form
UNSPECIFIED
Peak Reflow Temperature (Cel)
240
Number of Functions
1
Supply Voltage
5V
Frequency
DC~50kHz
[email protected] Reflow Temperature-Max (s)
30
Output
Ratiometric, Voltage
Pin Count
5
Qualification Status
Not Qualified
Number of Channels
1
Analog IC - Other Type
ANALOG CIRCUIT
Polarization
Bidirectional
Max Supply Current
10mA
Accuracy
±1%
Response Time
8μs
Sensor Type
Hall Effect, Open Loop
Linearity
±4.4%
Sensitivity
20mV/A
For Measuring
AC/DC
Current - Sensing
100A
Sensitivity (mV/A)
20 mV/A
RoHS Status
Non-RoHS Compliant
Lead Free
Contains Lead
ACS752SCA-100 Product Details
ACS752SCA-100 Overview
For safety reasons, the current sensors are enclosed in 5-CA Formed Leads packages. For protection, these current sensors are packaged in a Tube. A current sensor should provide a current no greater than 10mA. Current sensors terminate at 5. This current sensor has 5 pins. The current sensors are capable of supplying voltages of 5V while they are working. There are 5 pins on this electronic part.
ACS752SCA-100 Features
Moisture Sensitivity Level: 1 (Unlimited) Operating Temperature: -20°C~85°C 1 Channels Mounting Type: Through Hole Sensor Type: Hall Effect, Open Loop Supply Voltage: 5V Frequency: DC~50kHz Sensing Current: 100A 5-CA Formed Leads Package
ACS752SCA-100 Applications
There are a lot of Allegro MicroSystems ACS752SCA-100 Current Sensors applications.