NPA-700 Series Vented Gauge Pressure Sensor I2C -40°C~125°C 5PSI (34.47kPa) Barbed ±1.5% 14 b 4.75V~5.25V Temperature Compensated
SOT-23
NPA-700B-005G Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
13 Weeks
Mount
Surface Mount
Package / Case
14-SOIC Module, Top Port
Number of Pins
14
Operating Temperature
-40°C~125°C
Packaging
Cut Tape (CT)
Series
NPA-700
Published
2014
JESD-609 Code
e4
Feature
Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
5A (24 Hours)
Termination
Gull Wing
Terminal Finish
Nickel/Palladium/Gold (Ni/Pd/Au)
Applications
Board Mount
Voltage - Rated DC
5V
Voltage - Supply
4.75V~5.25V
Reach Compliance Code
unknown
Output
14 b
Termination Style
Gull Wing
Output Voltage
5V
Output Type
I2C
Operating Supply Voltage
5V
Impedance
5kOhm
Nominal Supply Current
1mA
Number of Bits
14
Accuracy
±1.5%
Operating Pressure
5PSI (34.47kPa)
Pressure Type
Vented Gauge
Port Style
Barbed
Resolution
1.75 B
Port Size
Male - 0.12 3mm Tube Dual
Linearity
0.25 %
Maximum Pressure
60PSI (413.69kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Max Pressure
60 PSI
Pressure Sensing Mode
GAGE
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
100
$19.51500
$1951.5
300
$18.86450
$5659.35
500
$18.21400
$9107
NPA-700B-005G Product Details
NPA-700B-005G Overview
Transducers in 14-SOIC Module, Top Port are included for convenience. For reliable performance, set the temperature of the transducers to -40°C~125°C. Supply voltages of 4.75V~5.25V are suitable for the transducers. This can only be accomplished by connecting 14 pins to the transducers. Cut Tape (CT) is the package number for this electronic component. It is possible for the transducers to operate normally at nominal supply currents of 1mA. To make the transducers work, the voltage released by them must be 5V. Transducers should be able to operate continuously at their rated ambient temperatures if the DC voltage is 5V.
NPA-700B-005G Features
Moisture Sensitivity Level: 5A (24 Hours) Package / Case: 14-SOIC Module, Top Port Operating Temperature: -40°C~125°C 14 Pins NPA-700 series Operating Pressure: 5PSI (34.47kPa) Operating Supply Voltage: 5V
NPA-700B-005G Applications
There are a lot of Amphenol Advanced Sensors NPA-700B-005G Transducers applications.