NPI-15VC Series Sealed Gauge Pressure Sensor Wheatstone Bridge -40°C~125°C 5000PSI (34473.79kPa) No Port ±0.35% 0 mV ~ 100 mV (10V) 10V~15V Temperature Compensated

SOT-23

NPI-15A-5K0SV Datasheet

non-compliant

In-Stock: 0 items
Specifications
Name Value
Type Parameter
Factory Lead Time 11 Weeks
Package / Case Cylinder
Operating Temperature -40°C~125°C
Series NPI-15VC
Feature Temperature Compensated
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Termination Cable
Max Operating Temperature 125°C
Min Operating Temperature -40°C
Applications Board Mount
Voltage - Supply 10V~15V
Output 0 mV ~ 100 mV (10V)
Termination Style Flex Cable
Output Voltage 200mV
Output Type Wheatstone Bridge
Operating Supply Current 1mA
Accuracy ±0.35%
Operating Pressure 5000PSI (34473.79kPa)
Pressure Type Sealed Gauge
Port Style No Port
Maximum Pressure 10000PSI (68947.57kPa)
RoHS Status RoHS Compliant
Lead Free Contains Lead
Pricing & Ordering
Quantity Unit Price Ext. Price
1 $86.850000 $86.85
10 $81.933962 $819.33962
100 $77.296191 $7729.6191
500 $72.920935 $36460.4675
1000 $68.793335 $68793.335
NPI-15A-5K0SV Product Details

NPI-15A-5K0SV Overview


This transducer is included in the Cylinder package for your convenience. Transducers should have their temperature set to -40°C~125°C for reliable operation. When the supply voltage is 10V~15V, the transducers will operate well. Transducers can be operated at temperatures up to 125°C. Transducers cannot be operated below -40°C. It should work with a voltage of 200mV.

NPI-15A-5K0SV Features


Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: Cylinder
Operating Temperature: -40°C~125°C
NPI-15VC series
Operating Pressure: 5000PSI (34473.79kPa)


NPI-15A-5K0SV Applications


There are a lot of Amphenol Advanced Sensors
NPI-15A-5K0SV Transducers applications.


  • Virtual Reality and Gaming Equipment
  • Indoor/Outdoor Navigation (dead-reckoning, floor/elevator/step detection)
  • Vertical velocity monitoring
  • Leisure, Sports, and Fitness Activity Identification
  • Weather Forecasting
  • Hydrogen Storage
  • Refrigerant pressure monitoring in HVAC/R systems
  • Dry air system pressure, process controls and automation
  • Dry air system monitoring
  • Hydraulic, brake, and engine oil fluid pressure monitoring

Related Part Number