19 mm Series Vented Gauge Pressure Sensor Analog Voltage -40°C~125°C 15PSI (103.42kPa) Threaded ±0.25% 0 mV ~ 100 mV (10V) Temperature Compensated
SOT-23
19C015PG4K Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
14 Weeks
Mount
Stud
Package / Case
Cylinder, Threaded
Number of Pins
4
Operating Temperature
-40°C~125°C
Packaging
Bulk
Series
19 mm
Published
2008
Feature
Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
Wire Leads
Applications
Board Mount
Voltage - Rated DC
15V
Reach Compliance Code
unknown
Output
0 mV ~ 100 mV (10V)
Termination Style
Flex Cable
Output Voltage
100mV
Output Type
Analog Voltage
Supply Voltage-Max (Vsup)
10V
Accuracy
±0.25%
Response Time
100 μs
Operating Pressure
15PSI (103.42kPa)
Pressure Type
Vented Gauge
Port Style
Threaded
Port Size
Male - 1/8 3.18mm NPT
Linearity
0.25 %
Maximum Pressure
45PSI (310.26kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
STAINLESS STEEL
Max Pressure
45 PSI
Pressure Range-Max
15 Psi
Pressure Sensing Mode
GAGE
Offset-Nom
0MV
Height
30.99mm
Length
21.98mm
Width
19.05mm
RoHS Status
RoHS Compliant
Lead Free
Lead Free
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$165.23000
$165.23
5
$154.90000
$774.5
10
$149.73700
$1497.37
25
$144.57400
$3614.35
50
$141.99260
$7099.63
19C015PG4K Product Details
19C015PG4K Overview
The Cylinder, Threaded package includes this transducer for convenience. In order to ensure reliable performance, the transducers should be set to -40°C~125°C. In order to make the transducers work properly, the 4 pins must be connected. This transducer has a maximum pressure range of 15 Psi. A Bulk package contains this electronic component. For it to work, the transducers should release 100mV voltage. To keep the transducers operating continuously at rated ambient temperatures, the DC voltage should be 15V.