CSLA Series Hall Effect, Open Loop Sensor 1-Channel Bidirectional -25°C~85°C 6V~12V 72A
SOT-23
CSLA2CD Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
4 Weeks
Mount
PCB
Mounting Type
Through Hole
Package / Case
Module, Single Pass Through
Number of Pins
3
Housing Material
PBT
Operating Temperature
-25°C~85°C
Packaging
Bulk
Series
CSLA
Published
1998
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
Connector
Max Operating Temperature
85°C
Min Operating Temperature
-25°C
Voltage - Supply
6V~12V
Current Rating
20mA
Output
Ratiometric, Voltage
Current - Supply (Max)
20mA
Output Type
Voltage
Polarity
Bidirectional
Number of Channels
1
Max Supply Voltage
12V
Min Supply Voltage
6V
Polarization
Bidirectional
Nominal Supply Current
20mA
Max Supply Current
20mA
Max Voltage Rating (DC)
13.2V
Response Time
3μs
Wire/Cable Diameter
10.9 mm
Sensor Type
Hall Effect, Open Loop
Sensing Method
Inductive
Sensitivity
32.7mV/N
Max Supply Voltage (DC)
13.2V
Min Supply Voltage (DC)
5.4V
For Measuring
AC/DC
Current - Sensing
72A
Height
35.56mm
Length
34.3mm
Width
10.414mm
REACH SVHC
Unknown
RoHS Status
RoHS Compliant
Lead Free
Lead Free
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$226.719540
$226.71954
10
$213.886359
$2138.86359
100
$201.779584
$20177.9584
500
$190.358098
$95179.049
1000
$179.583111
$179583.111
CSLA2CD Product Details
CSLA2CD Overview
Current sensors are housed in Module, Single Pass Through packages to ensure their safety. It is designed to protect the current sensors from damage by packaging them in the Bulk. In general, current sensors should provide no more than 20mA amps of current. In order for current sensors to be effective, their current supply should not exceed 20mA. This current sensor must operate at a temperature greater than -25°C. Nevertheless, the current sensors should be set to 85°C as the maximum operating temperature. Current sensors are designed to detect 20mA current. The current sensor has 3 pins. By definition, current sensors should provide a 20mA current. Sensors should supply voltages above 5.4V in DC circuits. As long as the DC circuit is not overvoltaged, the voltage supplied by the current sensors should not exceed 13.2V.
CSLA2CD Features
Moisture Sensitivity Level: 1 (Unlimited) Operating Temperature: -25°C~85°C 1 Channels Mounting Type: Through Hole Sensor Type: Hall Effect, Open Loop Supply Voltage: 6V~12V Sensing Current: 72A Module, Single Pass Through Package
CSLA2CD Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA2CD Current Sensors applications.