CSLA Series Hall Effect, Open Loop Sensor 1-Channel Bidirectional -25°C~85°C 6V~12V 310A
SOT-23
CSLA2EJ Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
27 Weeks
Mount
Through Hole
Mounting Type
Through Hole
Package / Case
Module, Single Pass Through
Number of Pins
3
Operating Temperature
-25°C~85°C
Packaging
Bulk
Series
CSLA
Published
1998
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Max Operating Temperature
85°C
Min Operating Temperature
-25°C
Voltage - Supply
6V~12V
Current Rating
20mA
Output
Ratiometric, Voltage
Current - Supply (Max)
20mA
Operating Supply Voltage
9V
Polarity
Bidirectional
Number of Channels
1
Max Supply Voltage
12V
Min Supply Voltage
6V
Polarization
Bidirectional
Nominal Supply Current
20mA
Max Supply Current
20mA
Response Time
3μs
Sensor Type
Hall Effect, Open Loop
Sensitivity
7.6mV/N
Max Supply Voltage (DC)
12V
Min Supply Voltage (DC)
6V
For Measuring
AC/DC
Current - Sensing
310A
REACH SVHC
Unknown
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$61.34000
$61.34
5
$58.27400
$291.37
10
$53.67300
$536.73
25
$47.53840
$1188.46
50
$46.00500
$2300.25
100
$44.47150
$4447.15
CSLA2EJ Product Details
CSLA2EJ Overview
Current sensors are housed in Module, Single Pass Through packages to ensure their safety. It is designed to protect the current sensors from damage by packaging them in the Bulk. In general, current sensors should provide no more than 20mA amps of current. In order for current sensors to be effective, their current supply should not exceed 20mA. This current sensor must operate at a temperature greater than -25°C. Nevertheless, the current sensors should be set to 85°C as the maximum operating temperature. Current sensors are designed to detect 20mA current. The current sensor has 3 pins. As they operate, the current sensors may provide 9V voltage. By definition, current sensors should provide a 20mA current. Sensors should supply voltages above 6V in DC circuits. As long as the DC circuit is not overvoltaged, the voltage supplied by the current sensors should not exceed 12V.
CSLA2EJ Features
Moisture Sensitivity Level: 1 (Unlimited) Operating Temperature: -25°C~85°C 1 Channels Mounting Type: Through Hole Sensor Type: Hall Effect, Open Loop Supply Voltage: 6V~12V Sensing Current: 310A Module, Single Pass Through Package
CSLA2EJ Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA2EJ Current Sensors applications.