CSN Series Hall Effect, Closed Loop Sensor 1-Channel Bidirectional -40°C~85°C ±12V~15V 150kHz 90A Accuracy-±0.5% Linearity-0.1 %
SOT-23
CSNP661 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
9 Weeks
Mount
PCB
Mounting Type
Through Hole
Package / Case
Module, Single Pass Through
Number of Pins
3
Housing Material
PBT
Operating Temperature
-40°C~85°C
Packaging
Bulk
Series
CSN
Published
1998
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
Solder
Type
Hall Effect
Max Operating Temperature
85°C
Min Operating Temperature
-40°C
Voltage - Supply
±12V~15V
Current Rating
90A
Frequency
150kHz
Output
Ratiometric, Current
Current - Supply (Max)
10mA
Polarity
Bidirectional
Number of Channels
1
Max Supply Voltage
15V
Min Supply Voltage
12V
Polarization
Bidirectional
Nominal Supply Current
10mA
Output Current
50mA
Max Supply Current
10mA
Accuracy
±0.5%
Response Time
0.5μs
Coil Resistance
30Ohm
Hole Diameter
13.5 mm
Sensor Type
Hall Effect, Closed Loop
Max Frequency
150kHz
Linearity
0.1 %
Sensing Method
Hall Effect
Max Supply Voltage (DC)
15V
Min Supply Voltage (DC)
12V
For Measuring
AC/DC
Current - Sensing
90A
Height
29.8mm
Width
36.5mm
REACH SVHC
No SVHC
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$50.67000
$50.67
5
$48.36400
$241.82
10
$43.75700
$437.57
25
$40.30240
$1007.56
50
$35.69660
$1784.83
100
$34.54500
$3454.5
CSNP661 Product Details
CSNP661 Overview
The current sensors are put into Module, Single Pass Through packages for safety protection. These current sensors are packaged in the Bulk to protect the devices from damage. The maximum current supplied by these current sensors should be 10mA. The current supplied by current sensors should not be higher than 10mA. The operating temperature must not be lower than -40°C to ensure these current sensors work. But the maximum operating temperature for the current sensors should be set to 85°C. The current for which the current sensors have been designed is 90A. There are 3 pins in this current sensor. Nominally, the current supplied by current sensors should be 10mA. The current output from current sensors should be 50mA. In a DC circuit, the voltage supplied by these sensors should not be lower than 12V. But the voltage supplied by the current sensors should not exceed 15V in the DC circuit.
CSNP661 Features
Moisture Sensitivity Level: 1 (Unlimited) Operating Temperature: -40°C~85°C 1 Channels Mounting Type: Through Hole Sensor Type: Hall Effect, Closed Loop Supply Voltage: ±12V~15V Frequency: 150kHz Sensing Current: 90A Module, Single Pass Through Package
CSNP661 Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSNP661 Current Sensors applications.