TruStability® HSC Series Vented Gauge Pressure Sensor Analog Voltage -20°C~85°C 14.5PSI (100kPa) Barbed ±0.25% 0.33 V ~ 2.97 V 3V~3.6V Amplified Output, Temperature Compensated
SOT-23
HSCDANN001BGAA3 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
10 Weeks
Mount
Through Hole
Package / Case
8-DIP (0.524, 13.30mm), Top Port
Number of Pins
8
Operating Temperature
-20°C~85°C
Series
TruStability® HSC
Published
2011
Feature
Amplified Output, Temperature Compensated
Pbfree Code
yes
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PC Pin
Applications
Board Mount
Additional Feature
TEMPERATURE COMPENSATED OVER 0 TO 50 DEG
Voltage - Rated DC
3.3V
Voltage - Supply
3V~3.6V
Reach Compliance Code
unknown
Output
0.33 V ~ 2.97 V
Termination Style
PC Pin
Body Length or Diameter
13.35mm
Body Breadth
9.91 mm
Output Voltage
2.97V
Output Type
Analog Voltage
Operating Supply Voltage
3.3V
Nominal Supply Current
1.6mA
Max Supply Current
2.1mA
Number of Bits
12
Accuracy
±0.25%
Response Time
1 ms
Operating Pressure
14.5PSI (100kPa)
Pressure Type
Vented Gauge
Port Style
Barbed
Port Size
Male - 0.19 4.93mm Tube
Maximum Pressure
29.01PSI (200kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
CERAMIC
Max Pressure
29.01 PSI
Pressure Range-Max
14.5 Psi
Pressure Sensing Mode
ABSOLUTE
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$38.655460
$38.65546
10
$36.467415
$364.67415
100
$34.403222
$3440.3222
500
$32.455870
$16227.935
1000
$30.618745
$30618.745
HSCDANN001BGAA3 Product Details
HSCDANN001BGAA3 Overview
This transducer was included in the 8-DIP (0.524, 13.30mm), Top Port package for the convenience of the user. In order to ensure reliable operation, it is recommended that the transducers be set to -20°C~85°C. It has been found that the transducers are capable of operating at supply voltages of 3V~3.6V. To make the transducers work, you have to connect the 8 pins. It is possible to set the maximum pressure range for this transducer to 14.5 Psi. In the case of transducers, normal operation may be achieved with a nominal supply current of 1.6mA. This device requires a voltage release from the transducers of 2.97V to function effectively. To keep transducers operating at rated ambient temperatures, DC voltage should be 3.3V. The current of the transducers should not exceed 2.1mA, otherwise it will be dangerous.
HSCDANN001BGAA3 Features
Moisture Sensitivity Level: 1 (Unlimited) Package / Case: 8-DIP (0.524, 13.30mm), Top Port Operating Temperature: -20°C~85°C 8 Pins TruStability® HSC series Operating Pressure: 14.5PSI (100kPa) Operating Supply Voltage: 3.3V
HSCDANN001BGAA3 Applications
There are a lot of Honeywell Sensing and Productivity Solutions HSCDANN001BGAA3 Transducers applications.
Weather Forecasting
Hydrogen Storage
Refrigerant pressure monitoring in HVAC/R systems
Dry air system pressure, process controls and automation
Dry air system monitoring
Hydraulic, brake, and engine oil fluid pressure monitoring