TruStability® HSC Series Vented Gauge Pressure Sensor I2C -20°C~85°C 1PSI (6.89kPa) Barbed ±0.25% 12 b 4.75V~5.25V Amplified Output, Temperature Compensated

SOT-23

HSCDANN001PG2A5 Datasheet

non-compliant

In-Stock: 0 items
Specifications
Name Value
Type Parameter
Factory Lead Time 11 Weeks
Mount Through Hole
Package / Case 8-DIP (0.524, 13.30mm), Top Port
Number of Pins 8
Operating Temperature -20°C~85°C
Series TruStability® HSC
Published 2011
Feature Amplified Output, Temperature Compensated
Pbfree Code yes
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Termination PCB
Applications Board Mount
Voltage - Rated DC 5V
Voltage - Supply 4.75V~5.25V
Output 12 b
Termination Style PC Pin
Body Length or Diameter 12.45mm
Body Breadth 9.91 mm
Output Type I2C
Operating Supply Voltage 5V
Nominal Supply Current 2mA
Max Supply Current 3mA
Number of Bits 12
Accuracy ±0.25%
Response Time 1 ms
Operating Pressure 1PSI (6.89kPa)
Pressure Type Vented Gauge
Port Style Barbed
Port Size Male - 0.19 4.93mm Tube
Maximum Pressure 10PSI (68.95kPa)
Sensors/Transducers Type PRESSURE SENSOR,PEIZORESISTIVE
Housing CERAMIC
Max Pressure 10 PSI
Pressure Range-Max 1 Psi
Pressure Sensing Mode GAGE
RoHS Status RoHS Compliant
Pricing & Ordering
Quantity Unit Price Ext. Price
1 $45.77000 $45.77
5 $43.68600 $218.43
10 $39.52600 $395.26
25 $36.40560 $910.14
50 $32.24500 $1612.25
100 $31.20490 $3120.49
HSCDANN001PG2A5 Product Details

HSCDANN001PG2A5 Overview


As a convenience, the transducer is included in the package 8-DIP (0.524, 13.30mm), Top Port. Ensure reliable performance by setting the transducers to -20°C~85°C. With a supply voltage of 4.75V~5.25V, the transducers can operate efficiently. The transducers are not able to work properly without the 8 pins being connected. There is a maximum range of pressure set by this transducer of 1 Psi. Transducers can operate normally with a nominal supply current of 2mA. Transducers should operate continuously at their rated ambient temperature if the DC voltage is set to 5V. The current of the transducers should not exceed 3mA, otherwise it will be dangerous.

HSCDANN001PG2A5 Features


Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: 8-DIP (0.524, 13.30mm), Top Port
Operating Temperature: -20°C~85°C
8 Pins
TruStability® HSC series
Operating Pressure: 1PSI (6.89kPa)
Operating Supply Voltage: 5V


HSCDANN001PG2A5 Applications


There are a lot of Honeywell Sensing and Productivity Solutions
HSCDANN001PG2A5 Transducers applications.


  • Virtual Reality and Gaming Equipment
  • Indoor/Outdoor Navigation (dead-reckoning, floor/elevator/step detection)
  • Vertical velocity monitoring
  • Leisure, Sports, and Fitness Activity Identification
  • Weather Forecasting
  • Hydrogen Storage
  • Refrigerant pressure monitoring in HVAC/R systems
  • Dry air system pressure, process controls and automation
  • Dry air system monitoring
  • Hydraulic, brake, and engine oil fluid pressure monitoring

Related Part Number