TruStability® HSC Series Vented Gauge Pressure Sensor SPI -20°C~85°C 5PSI (34.47kPa) Barbed ±0.25% 12 b 4.75V~5.25V Amplified Output, Temperature Compensated
SOT-23
HSCDANN005PGSA5 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
9 Weeks
Mount
Through Hole
Package / Case
8-DIP (0.524, 13.30mm), Top Port
Number of Pins
8
Operating Temperature
-20°C~85°C
Series
TruStability® HSC
Published
2009
Feature
Amplified Output, Temperature Compensated
Pbfree Code
yes
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PC Pin
Applications
Board Mount
Voltage - Rated
5V
Voltage - Rated DC
5V
Voltage - Supply
4.75V~5.25V
Output
12 b
Termination Style
PC Pin
Body Breadth
9.91 mm
Output Type
SPI
Operating Supply Voltage
5V
Nominal Supply Current
2mA
Max Supply Current
3mA
Number of Bits
12
Accuracy
±0.25%
Response Time
1 ms
Operating Pressure
5PSI (34.47kPa)
Pressure Type
Vented Gauge
Port Style
Barbed
Port Size
Male - 0.19 4.93mm Tube
Maximum Pressure
30PSI (206.84kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
CERAMIC
Max Pressure
30 PSI
Pressure Range-Max
5 Psi
Pressure Sensing Mode
GAGE
Height
13.75mm
Length
10mm
Width
6.99mm
REACH SVHC
Unknown
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$94.840000
$94.84
10
$89.471698
$894.71698
100
$84.407262
$8440.7262
500
$79.629493
$39814.7465
1000
$75.122163
$75122.163
HSCDANN005PGSA5 Product Details
HSCDANN005PGSA5 Overview
This transducer is included in the package 8-DIP (0.524, 13.30mm), Top Port. Ensure reliable performance by setting the transducers' temperature to -20°C~85°C. It is possible to use the transducers with a supply voltage of 4.75V~5.25V without any problems. Transducers need to be connected to 8 pins in order to function properly. This transducer can measure pressures up to 5 Psi. When the nominal supply current is 2mA, the transducers can operate normally. Transducers should receive a DC voltage of 5V in order to maintain the rated ambient temperature continuously. The current of the transducers should not exceed 3mA, otherwise it will be dangerous.
HSCDANN005PGSA5 Features
Moisture Sensitivity Level: 1 (Unlimited) Package / Case: 8-DIP (0.524, 13.30mm), Top Port Operating Temperature: -20°C~85°C 8 Pins TruStability® HSC series Operating Pressure: 5PSI (34.47kPa) Operating Supply Voltage: 5V
HSCDANN005PGSA5 Applications
There are a lot of Honeywell Sensing and Productivity Solutions HSCDANN005PGSA5 Transducers applications.