TruStability® HSC Series Vented Gauge Pressure Sensor Analog Voltage -20°C~85°C 145.04PSI (1000kPa) Barbed ±0.25% 0.5 V ~ 4.5 V 4.75V~5.25V Amplified Output, Temperature Compensated
SOT-23
HSCDANN010BGAA5 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
10 Weeks
Mount
Through Hole
Package / Case
8-DIP (0.524, 13.30mm), Top Port
Number of Pins
8
Operating Temperature
-20°C~85°C
Series
TruStability® HSC
Published
2011
Feature
Amplified Output, Temperature Compensated
Pbfree Code
yes
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PCB
Applications
Board Mount
Additional Feature
TEMPERATURE COMPENSATED OVER 0 TO 50 DEG
Voltage - Rated DC
5V
Voltage - Supply
4.75V~5.25V
Output
0.5 V ~ 4.5 V
Termination Style
PC Pin
Body Length or Diameter
13.35mm
Body Breadth
9.91 mm
Output Voltage
4.5V
Output Type
Analog Voltage
Operating Supply Voltage
5V
Nominal Supply Current
2mA
Max Supply Current
3mA
Number of Bits
12
Accuracy
±0.25%
Response Time
1 ms
Operating Pressure
145.04PSI (1000kPa)
Pressure Type
Vented Gauge
Port Style
Barbed
Port Size
Male - 0.19 4.93mm Tube
Maximum Pressure
246.56PSI (1700kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
CERAMIC
Max Pressure
246.56 PSI
Pressure Range-Max
145.03 Psi
Pressure Sensing Mode
ABSOLUTE
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
250
$23.39140
$5847.85
HSCDANN010BGAA5 Product Details
HSCDANN010BGAA5 Overview
As a convenience, the transducer is included in package 8-DIP (0.524, 13.30mm), Top Port. Reliable performance is ensured by setting the transducer temperature to -20°C~85°C. With a voltage supply of 4.75V~5.25V, the transducers can function properly. There is a requirement for connecting the 8 pins to make the transducer work properly. This transducer can handle pressures up to 145.03 Psi. Transducers working with 2mA supply current can function normally. In order for it to work, the voltage released by the transducers must be 4.5V. For the transducers to continuously work at the rated ambient temperature, DC voltage should be 5V. The current of the transducers should not exceed 3mA, otherwise it will be dangerous.
HSCDANN010BGAA5 Features
Moisture Sensitivity Level: 1 (Unlimited) Package / Case: 8-DIP (0.524, 13.30mm), Top Port Operating Temperature: -20°C~85°C 8 Pins TruStability® HSC series Operating Pressure: 145.04PSI (1000kPa) Operating Supply Voltage: 5V
HSCDANN010BGAA5 Applications
There are a lot of Honeywell Sensing and Productivity Solutions HSCDANN010BGAA5 Transducers applications.