Welcome to Hotenda.com Online Store!

logo
userjoin
Home

HSCDANN010BGAA5

HSCDANN010BGAA5

HSCDANN010BGAA5

Honeywell Sensing and Productivity Solutions

TruStability® HSC Series Vented Gauge Pressure Sensor Analog Voltage -20°C~85°C 145.04PSI (1000kPa) Barbed ±0.25% 0.5 V ~ 4.5 V 4.75V~5.25V Amplified Output, Temperature Compensated

SOT-23

HSCDANN010BGAA5 Datasheet

non-compliant

In-Stock: 0 items
Specifications
Name Value
Type Parameter
Factory Lead Time 10 Weeks
Mount Through Hole
Package / Case 8-DIP (0.524, 13.30mm), Top Port
Number of Pins 8
Operating Temperature -20°C~85°C
Series TruStability® HSC
Published 2011
Feature Amplified Output, Temperature Compensated
Pbfree Code yes
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Termination PCB
Applications Board Mount
Additional Feature TEMPERATURE COMPENSATED OVER 0 TO 50 DEG
Voltage - Rated DC 5V
Voltage - Supply 4.75V~5.25V
Output 0.5 V ~ 4.5 V
Termination Style PC Pin
Body Length or Diameter 13.35mm
Body Breadth 9.91 mm
Output Voltage 4.5V
Output Type Analog Voltage
Operating Supply Voltage 5V
Nominal Supply Current 2mA
Max Supply Current 3mA
Number of Bits 12
Accuracy ±0.25%
Response Time 1 ms
Operating Pressure 145.04PSI (1000kPa)
Pressure Type Vented Gauge
Port Style Barbed
Port Size Male - 0.19 4.93mm Tube
Maximum Pressure 246.56PSI (1700kPa)
Sensors/Transducers Type PRESSURE SENSOR,PEIZORESISTIVE
Housing CERAMIC
Max Pressure 246.56 PSI
Pressure Range-Max 145.03 Psi
Pressure Sensing Mode ABSOLUTE
RoHS Status RoHS Compliant
Pricing & Ordering
Quantity Unit Price Ext. Price
250 $23.39140 $5847.85
HSCDANN010BGAA5 Product Details

HSCDANN010BGAA5 Overview


As a convenience, the transducer is included in package 8-DIP (0.524, 13.30mm), Top Port. Reliable performance is ensured by setting the transducer temperature to -20°C~85°C. With a voltage supply of 4.75V~5.25V, the transducers can function properly. There is a requirement for connecting the 8 pins to make the transducer work properly. This transducer can handle pressures up to 145.03 Psi. Transducers working with 2mA supply current can function normally. In order for it to work, the voltage released by the transducers must be 4.5V. For the transducers to continuously work at the rated ambient temperature, DC voltage should be 5V. The current of the transducers should not exceed 3mA, otherwise it will be dangerous.

HSCDANN010BGAA5 Features


Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: 8-DIP (0.524, 13.30mm), Top Port
Operating Temperature: -20°C~85°C
8 Pins
TruStability® HSC series
Operating Pressure: 145.04PSI (1000kPa)
Operating Supply Voltage: 5V


HSCDANN010BGAA5 Applications


There are a lot of Honeywell Sensing and Productivity Solutions
HSCDANN010BGAA5 Transducers applications.


  • Indoor/Outdoor Navigation (dead-reckoning, floor/elevator/step detection)
  • Vertical velocity monitoring
  • Leisure, Sports, and Fitness Activity Identification
  • Weather Forecasting
  • Hydrogen Storage
  • Refrigerant pressure monitoring in HVAC/R systems
  • Dry air system pressure, process controls and automation
  • Dry air system monitoring
  • Hydraulic, brake, and engine oil fluid pressure monitoring
  • Air brake pressure monitoring