PX2 Series Sealed Gauge Pressure Sensor Analog Voltage -40°C~125°C 200PSI (1378.95kPa) Threaded ±0.25% 1 V ~ 6 V 4.75V~5.25V Temperature Compensated
SOT-23
PX2AN2XX200PSBCX Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
7 Weeks
Mount
Stud
Package / Case
Cylinder
Number of Pins
3
Operating Temperature
-40°C~125°C
Series
PX2
Published
2014
Feature
Temperature Compensated
Part Status
Obsolete
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
Connector
Max Operating Temperature
125°C
Min Operating Temperature
-40°C
Applications
Industrial Automation
Voltage - Supply
4.75V~5.25V
Output
1 V ~ 6 V
Termination Style
Connector
Output Type
Analog Voltage
Max Supply Voltage
30V
Min Supply Voltage
9V
Accuracy
±0.25%
Operating Pressure
200PSI (1378.95kPa)
Pressure Type
Sealed Gauge
Port Style
Threaded
Port Size
Male - 1/8 3.18mm NPT
Maximum Pressure
750PSI (5171.07kPa)
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$107.69000
$107.69
5
$102.02400
$510.12
PX2AN2XX200PSBCX Product Details
PX2AN2XX200PSBCX Overview
As a convenience, the transducer is included in package Cylinder. Reliable performance is ensured by setting the transducer temperature to -40°C~125°C. With a voltage supply of 4.75V~5.25V, the transducers can function properly. The transducers can operate at a temperature of 125°C. An operating temperature lower than -40°C is not allowed for the transducers. There is a requirement for connecting the 3 pins to make the transducer work properly. No damage can be caused to the transducers at a voltage of 30V. The transducers are capable of operating at a voltage of 9V.