Specifications
Name Value
Type Parameter
Factory Lead Time 11 Weeks
Mount Chassis Mount
Mounting Type Chassis Mount
Package / Case Box with Connector
Number of Pins 3
Housing Material PBT
Operating Temperature -40°C~125°C
Packaging Bulk
Published 2011
Series RTY
Tolerance 1.6%
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Voltage - Rated DC 5V
Technology Hall Effect
Depth 55mm
Output Analog Voltage
Termination Style Connector
Actuator Type Flatted Shaft
Operating Supply Voltage 5V
Accuracy 1.6 %
Min Output Voltage 500mV
Linearity ±1%
Sensing Method Hall Effect
Max Supply Voltage (DC) 5.5V
Min Supply Voltage (DC) 4.5V
For Measuring Rotary Position
Output Signal Clockwise Increase
Switching Current 25mA
Rotation Angle - Electrical, Mechanical 50° (±25°), Continuous
Measurement Range-Max 75 deg
Measurement Range-Min 25 deg
Length 40mm
Width 25mm
REACH SVHC Unknown
RoHS Status RoHS Compliant
Ratings IP67
Pricing & Ordering
Quantity Unit Price Ext. Price
1 $54.08000 $54.08
5 $51.61800 $258.09
10 $46.70200 $467.02
25 $43.01520 $1075.38
50 $38.09900 $1904.95
100 $36.87000 $3687
RTY050LVNAX Product Details

RTY050LVNAX Overview


Linear position measuring sensors are protected from damage by being packaged in a Box with Connector package. The electronic component in question is packaged in the Bulk. The linear position measuring sensor has 3 pins. DC circuits should not exceed 5V when measuring angle position. The supply voltage applied by the linear position measuring sensor should be 5V when it operates. A DC circuit cannot supply more voltage than 5.5V to a linear position measuring sensor. In the DC circuit, however, the linear position measuring sensor cannot apply voltage below 4.5V. A linear position measuring sensor cannot release a voltage lower than 500mV.

RTY050LVNAX Features


Operating Temperature: -40°C~125°C
RTY Series
Mount: Chassis Mount
Package / Case: Box with Connector
Mounting Type: Chassis Mount
3 Pins

RTY050LVNAX Applications


There are a lot of Honeywell Sensing and Productivity Solutions RTY050LVNAX Angle & Linear Position Measuring Sensors applications.

  • Dishwasher control systems
  • Robotic joint position detection
  • X, Y, Z stage position feedback
  • Tilt/trim position (boat engines, tlling equipment)
  • Battery-powered applications
  • Non-contact potentiometer
  • Cylinder and valve position sensing
  • Float-Level Sensor
  • EGR valve position
  • Throttle Position Sensor

Related Part Number