TruStability® SSC Series Vented Gauge Pressure Sensor Analog Voltage -40°C~85°C 1PSI (6.89kPa) Barbed ±0.25% 0.33 V ~ 2.97 V 3V~3.6V Amplified Output, Temperature Compensated
SOT-23
SSCDANN001PGAA3 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
10 Weeks
Package / Case
8-DIP (0.524, 13.30mm), Top Port
Surface Mount
NO
Mounting Feature
THROUGH HOLE MOUNT
Number of Pins
8
Operating Temperature
-40°C~85°C
Series
TruStability® SSC
Published
2011
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Applications
Board Mount
Voltage - Supply
3V~3.6V
Reach Compliance Code
unknown
Output
0.33 V ~ 2.97 V
Termination Style
PC Pin
Output Type
Analog Voltage
Nominal Supply Current
1.6mA
Accuracy
±0.25%
Response Time
1 ms
Operating Pressure
1PSI (6.89kPa)
Pressure Type
Vented Gauge
Port Style
Barbed
Port Size
Male - 0.19 4.93mm Tube
Maximum Pressure
10PSI (68.95kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
CERAMIC
Pressure Range-Max
1 Psi
Pressure Sensing Mode
GAGE
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
250
$20.92352
$5230.88
SSCDANN001PGAA3 Product Details
SSCDANN001PGAA3 Overview
As a convenience, this transducer is included in 8-DIP (0.524, 13.30mm), Top Port. Temperature should be set at -40°C~85°C on transducers in order for them to work reliably. Obtaining a 3V~3.6V supply voltage is not a problem for the transducers. To ensure proper operation of the transducers, it is necessary to connect the 8 pins. There is a maximum pressure range of 1 Psi set by this transducer. A nominal supply current of 1.6mA can run the transducers normally.
SSCDANN001PGAA3 Features
Moisture Sensitivity Level: 1 (Unlimited) Package / Case: 8-DIP (0.524, 13.30mm), Top Port Operating Temperature: -40°C~85°C 8 Pins TruStability® SSC series Operating Pressure: 1PSI (6.89kPa)
SSCDANN001PGAA3 Applications
There are a lot of Honeywell Sensing and Productivity Solutions SSCDANN001PGAA3 Transducers applications.
Hydrogen Storage
Refrigerant pressure monitoring in HVAC/R systems
Dry air system pressure, process controls and automation
Dry air system monitoring
Hydraulic, brake, and engine oil fluid pressure monitoring