TruStability® SSC Series Absolute Pressure Sensor Analog Voltage -40°C~85°C 15PSI (103.42kPa) Barbed ±0.25% 0.5 V ~ 4.5 V 4.75V~5.25V Amplified Output, Temperature Compensated
SOT-23
SSCDANN015PAAA5 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
9 Weeks
Mount
Through Hole
Package / Case
8-DIP (0.524, 13.30mm), Top Port
Number of Pins
8
Operating Temperature
-40°C~85°C
Series
TruStability® SSC
Published
2011
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PCB
Applications
Board Mount
Voltage - Rated DC
5V
Voltage - Supply
4.75V~5.25V
Output
0.5 V ~ 4.5 V
Termination Style
PC Pin
Output Voltage
4.5V
Output Type
Analog Voltage
Operating Supply Voltage
5V
Nominal Supply Current
2mA
Max Supply Current
3mA
Accuracy
±0.25%
Response Time
1 ms
Operating Pressure
15PSI (103.42kPa)
Pressure Type
Absolute
Port Style
Barbed
Port Size
Male - 0.19 4.93mm Tube
Maximum Pressure
30PSI (206.84kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
CERAMIC
Max Pressure
30 PSI
Pressure Range-Max
15 Psi
Height
13.75mm
Length
10mm
Width
13.3mm
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$302.425600
$302.4256
10
$285.307170
$2853.0717
100
$269.157707
$26915.7707
500
$253.922365
$126961.1825
1000
$239.549401
$239549.401
SSCDANN015PAAA5 Product Details
SSCDANN015PAAA5 Overview
This transducer is included in the package 8-DIP (0.524, 13.30mm), Top Port. Ensure reliable performance by setting the transducers' temperature to -40°C~85°C. It is possible to use the transducers with a supply voltage of 4.75V~5.25V without any problems. Transducers need to be connected to 8 pins in order to function properly. This transducer can measure pressures up to 15 Psi. When the nominal supply current is 2mA, the transducers can operate normally. To make it work, the transducers must release 4.5V of voltage. Transducers should receive a DC voltage of 5V in order to maintain the rated ambient temperature continuously. The current of the transducers should not exceed 3mA, otherwise it will be dangerous.
SSCDANN015PAAA5 Features
Moisture Sensitivity Level: 1 (Unlimited) Package / Case: 8-DIP (0.524, 13.30mm), Top Port Operating Temperature: -40°C~85°C 8 Pins TruStability® SSC series Operating Pressure: 15PSI (103.42kPa) Operating Supply Voltage: 5V
SSCDANN015PAAA5 Applications
There are a lot of Honeywell Sensing and Productivity Solutions SSCDANN015PAAA5 Transducers applications.