TruStability® SSC Series Vented Gauge Pressure Sensor Analog Voltage -40°C~85°C 3.63PSI (25kPa) Barbed ±0.25% 0.5 V ~ 4.5 V 4.75V~5.25V Amplified Output, Temperature Compensated
SOT-23
SSCDRNN250MGAA5 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
9 Weeks
Package / Case
8-DIP (0.524, 13.30mm), Side Port
Surface Mount
NO
Mounting Feature
THROUGH HOLE MOUNT
Number of Pins
8
Operating Temperature
-40°C~85°C
Series
TruStability® SSC
Published
2011
Feature
Amplified Output, Temperature Compensated
Pbfree Code
yes
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PCB
Applications
Board Mount
Voltage - Rated DC
5V
Voltage - Supply
4.75V~5.25V
Reach Compliance Code
unknown
Output
0.5 V ~ 4.5 V
Termination Style
PC Pin
Body Breadth
9.91 mm
Output Voltage
4.5V
Output Type
Analog Voltage
Operating Supply Voltage
5V
Nominal Supply Current
2mA
Max Supply Current
3mA
Accuracy
±0.25%
Response Time
1 ms
Operating Pressure
3.63PSI (25kPa)
Pressure Type
Vented Gauge
Port Style
Barbed
Port Size
Male - 0.08 1.93mm Tube
Maximum Pressure
20.31PSI (140kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
CERAMIC
Max Pressure
20.31 PSI
Pressure Range-Max
3.63 Psi
Pressure Sensing Mode
GAGE
Body Height
5.9mm
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$31.75000
$31.75
5
$30.30400
$151.52
10
$27.41700
$274.17
25
$25.25240
$631.31
50
$22.36660
$1118.33
100
$21.64500
$2164.5
SSCDRNN250MGAA5 Product Details
SSCDRNN250MGAA5 Overview
As a convenience, this transducer is included in 8-DIP (0.524, 13.30mm), Side Port. Temperature should be set at -40°C~85°C on transducers in order for them to work reliably. Obtaining a 4.75V~5.25V supply voltage is not a problem for the transducers. To ensure proper operation of the transducers, it is necessary to connect the 8 pins. There is a maximum pressure range of 3.63 Psi set by this transducer. A nominal supply current of 2mA can run the transducers normally. In order for the transducers to work, the voltage discharged by them should be 4.5V. If the transducer is designed to operate continuously at the rated ambient temperature, then the DC voltage should be 5V. The current of the transducers should not exceed 3mA, otherwise it will be dangerous.
SSCDRNN250MGAA5 Features
Moisture Sensitivity Level: 1 (Unlimited) Package / Case: 8-DIP (0.524, 13.30mm), Side Port Operating Temperature: -40°C~85°C 8 Pins TruStability® SSC series Operating Pressure: 3.63PSI (25kPa) Operating Supply Voltage: 5V
SSCDRNN250MGAA5 Applications
There are a lot of Honeywell Sensing and Productivity Solutions SSCDRNN250MGAA5 Transducers applications.
Hydrogen Storage
Refrigerant pressure monitoring in HVAC/R systems
Dry air system pressure, process controls and automation
Dry air system monitoring
Hydraulic, brake, and engine oil fluid pressure monitoring