TruStability® SSC Series Differential Pressure Sensor Analog Voltage -40°C~85°C ±0.36PSI (±2.5kPa) Barbed ±0.25% 0.33 V ~ 2.97 V 3.27V~3.33V Amplified Output, Temperature Compensated
SOT-23
SSCDRRN025MDAA3 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
12 Weeks
Mount
Through Hole
Package / Case
8-DIP (0.524, 13.30mm), Dual Ports, Same Side
Number of Pins
8
Operating Temperature
-40°C~85°C
Series
TruStability® SSC
Published
2007
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PC Pin
Applications
Board Mount
Voltage - Rated
3.3V
Voltage - Rated DC
3.3V
Voltage - Supply
3.27V~3.33V
Output
0.33 V ~ 2.97 V
Termination Style
PC Pin
Output Type
Analog Voltage
Operating Supply Voltage
3.3V
Nominal Supply Current
2mA
Number of Bits
14
Accuracy
±0.25%
Response Time
1 ms
Operating Pressure
±0.36PSI (±2.5kPa)
Pressure Type
Differential
Port Style
Barbed
Port Size
Male - 0.08 1.93mm Tube Dual
Maximum Pressure
±12.33PSI (±85kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Max Supply Voltage (DC)
3.33V
Min Supply Voltage (DC)
3.27V
Housing
CERAMIC
Max Pressure
12.33 PSI
Pressure Range-Max
0.363 Psi
Height
6.16mm
Length
10mm
Width
6.99mm
REACH SVHC
No SVHC
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$50.05000
$50.05
5
$47.77600
$238.88
10
$43.22500
$432.25
25
$39.81240
$995.31
50
$35.26260
$1763.13
100
$34.12500
$3412.5
SSCDRRN025MDAA3 Product Details
SSCDRRN025MDAA3 Overview
This transducer is included in the package 8-DIP (0.524, 13.30mm), Dual Ports, Same Side for your convenience. For reliable performance, the transducers should be set to -40°C~85°C. The transducers are capable of operating with a supply voltage of 3.27V~3.33V. There is a requirement that 8 pins be connected for the transducers to function properly. A transducer of this type can measure pressures up to 0.363 Psi. When the supply current is set to 2mA, the transducers will operate normally. For the transducers to operate continuously at ambient temperatures, the DC voltage should be set to 3.3V.