TruStability® SSC Series Vented Gauge Pressure Sensor Analog Voltage -40°C~85°C 30PSI (206.84kPa) Barbed ±0.25% 0.5 V ~ 4.5 V 4.75V~5.25V Amplified Output, Temperature Compensated
SOT-23
SSCSAAN030PGAA5 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
10 Weeks
Package / Case
4-SIP, Dual Ports, Opposite Sides
Surface Mount
NO
Mounting Feature
THROUGH HOLE MOUNT
Number of Pins
4
Operating Temperature
-40°C~85°C
Series
TruStability® SSC
Published
2011
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PCB
Applications
Board Mount
Additional Feature
TEMPERATURE COMPENSATED OVER -20 TO 85 DEG
Voltage - Rated DC
5V
Voltage - Supply
4.75V~5.25V
Reach Compliance Code
unknown
Output
0.5 V ~ 4.5 V
Termination Style
PC Pin
Output Voltage
4.5V
Output Type
Analog Voltage
Operating Supply Voltage
5V
Nominal Supply Current
2mA
Max Supply Current
3mA
Accuracy
±0.25%
Response Time
1 ms
Operating Pressure
30PSI (206.84kPa)
Pressure Type
Vented Gauge
Port Style
Barbed
Port Size
Male - 0.19 4.93mm Tube Dual
Maximum Pressure
60PSI (413.69kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
CERAMIC
Pressure Range-Max
30 Psi
Pressure Sensing Mode
GAGE
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
250
$22.62000
$5655
SSCSAAN030PGAA5 Product Details
SSCSAAN030PGAA5 Overview
This transducer is included in the 4-SIP, Dual Ports, Opposite Sides package for your convenience. Transducers should have their temperature set to -40°C~85°C for reliable operation. When the supply voltage is 4.75V~5.25V, the transducers will operate well. The transducers can only function properly if the 4 pins are connected. Its maximum pressure range is 30 Psi. With nominal supply current of 2mA, the transducers will function normally. It should work with a voltage of 4.5V. It is important that the DC voltage be set to 5V to ensure that transducers are continuously capable of operating at the rated ambient temperature. The current of the transducers should not exceed 3mA, otherwise it will be dangerous.