TruStability® SSC Series Absolute Pressure Sensor Analog Voltage -40°C~85°C 14.5PSI (100kPa) Barbed ±0.25% 0.33 V ~ 2.97 V 3V~3.6V Amplified Output, Temperature Compensated
SOT-23
SSCSANN001BAAA3 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
9 Weeks
Mount
Through Hole
Package / Case
4-SIP, Side Port
Number of Pins
4
Operating Temperature
-40°C~85°C
Series
TruStability® SSC
Published
2011
Feature
Amplified Output, Temperature Compensated
Pbfree Code
yes
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PC Pin
Applications
Board Mount
Additional Feature
TEMPERATURE COMPENSATED OVER -20 TO 85 DEG
Voltage - Rated DC
3.3V
Voltage - Supply
3V~3.6V
Reach Compliance Code
unknown
Output
0.33 V ~ 2.97 V
Termination Style
PC Pin
Body Length or Diameter
13.85mm
Body Breadth
9.91 mm
Output Voltage
2.97V
Output Type
Analog Voltage
Operating Supply Voltage
3.3V
Nominal Supply Current
1.6mA
Max Supply Current
2.1mA
Number of Bits
12
Accuracy
±0.25%
Response Time
1 ms
Operating Pressure
14.5PSI (100kPa)
Pressure Type
Absolute
Port Style
Barbed
Port Size
Male - 0.19 4.93mm Tube
Maximum Pressure
29.01PSI (200kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
CERAMIC
Max Pressure
29.01 PSI
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$44.29000
$44.29
5
$42.27400
$211.37
10
$38.24700
$382.47
25
$35.22760
$880.69
50
$31.20160
$1560.08
100
$30.19500
$3019.5
SSCSANN001BAAA3 Product Details
SSCSANN001BAAA3 Overview
As a convenience, this transducer is included in 4-SIP, Side Port. Temperature should be set at -40°C~85°C on transducers in order for them to work reliably. Obtaining a 3V~3.6V supply voltage is not a problem for the transducers. To ensure proper operation of the transducers, it is necessary to connect the 4 pins. A nominal supply current of 1.6mA can run the transducers normally. In order for the transducers to work, the voltage discharged by them should be 2.97V. If the transducer is designed to operate continuously at the rated ambient temperature, then the DC voltage should be 3.3V. The current of the transducers should not exceed 2.1mA, otherwise it will be dangerous.
SSCSANN001BAAA3 Features
Moisture Sensitivity Level: 1 (Unlimited) Package / Case: 4-SIP, Side Port Operating Temperature: -40°C~85°C 4 Pins TruStability® SSC series Operating Pressure: 14.5PSI (100kPa) Operating Supply Voltage: 3.3V
SSCSANN001BAAA3 Applications
There are a lot of Honeywell Sensing and Productivity Solutions SSCSANN001BAAA3 Transducers applications.
Hydrogen Storage
Refrigerant pressure monitoring in HVAC/R systems
Dry air system pressure, process controls and automation
Dry air system monitoring
Hydraulic, brake, and engine oil fluid pressure monitoring