TruStability® SSC Series Vented Gauge Pressure Sensor Analog Voltage -40°C~85°C 1.45PSI (10kPa) No Port ±0.25% 0.2 V ~ 4.7 V 4.75V~5.25V Amplified Output, Temperature Compensated
SOT-23
SSCSMNN010KGAF5 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
7 Weeks
Package / Case
4-SIP Module
Supplier Device Package
4-SIP
Operating Temperature
-40°C~85°C
Series
TruStability® SSC
Published
2011
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PCB
Max Operating Temperature
85°C
Min Operating Temperature
-20°C
Applications
Board Mount
Voltage - Rated DC
5V
Voltage - Supply
4.75V~5.25V
Output
0.2 V ~ 4.7 V
Termination Style
PC Pin
Output Type
Analog Voltage
Operating Supply Voltage
5V
Max Supply Voltage
5.25V
Min Supply Voltage
4.75V
Nominal Supply Current
2mA
Accuracy
±0.25%
Operating Pressure
1.45PSI (10kPa)
Pressure Type
Vented Gauge
Port Style
No Port
Maximum Pressure
12.33PSI (85kPa)
Max Pressure
12.33 PSI
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$49.060000
$49.06
10
$46.283019
$462.83019
100
$43.663225
$4366.3225
500
$41.191722
$20595.861
1000
$38.860115
$38860.115
SSCSMNN010KGAF5 Product Details
SSCSMNN010KGAF5 Overview
As a convenience, this transducer is included in 4-SIP Module. Temperature should be set at -40°C~85°C on transducers in order for them to work reliably. Obtaining a 4.75V~5.25V supply voltage is not a problem for the transducers. It is possible for the transducers to operate at a maximum temperature of 85°C. Temperatures below -20°C are unacceptable for the transducers. A nominal supply current of 2mA can run the transducers normally. If the transducer is designed to operate continuously at the rated ambient temperature, then the DC voltage should be 5V. You can apply a voltage of 5.25V without damaging the transducers. Minimum supply voltage 4.75V is required for the transducers to operate.