Honeywell Sensing and Productivity Solutions

TruStability® SSC Series Differential Pressure Sensor Analog Voltage -40°C~85°C ±15PSI (±103.42kPa) Barbless ±0.25% 0.5 V ~ 4.5 V 4.75V~5.25V Amplified Output, Temperature Compensated

SOT-23

SSCSNBN015PDAA5 Datasheet

non-compliant

In-Stock: 0 items
Specifications
Name Value
Type Parameter
Factory Lead Time 12 Weeks
Package / Case 4-SIP, Dual Ports, Same Side
Surface Mount NO
Mounting Feature THROUGH HOLE MOUNT
Number of Pins 4
Operating Temperature -40°C~85°C
Series TruStability® SSC
Published 2007
Feature Amplified Output, Temperature Compensated
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Termination PC Pin
Applications Board Mount
Voltage - Rated 5V
Additional Feature TEMPERATURE COMPENSATED OVER -20 TO 85 DEG
Voltage - Rated DC 5V
Voltage - Supply 4.75V~5.25V
Output 0.5 V ~ 4.5 V
Termination Style PC Pin
Output Voltage 4.5V
Output Type Analog Voltage
Operating Supply Voltage 5V
Operating Supply Current 2mA
Nominal Supply Current 2mA
Max Supply Current 3mA
Accuracy ±0.25%
Response Time 1 ms
Operating Pressure ±15PSI (±103.42kPa)
Pressure Type Differential
Port Style Barbless
Port Size Male - 0.19 4.8mm Tube Dual
Maximum Pressure ±60PSI (±413.69kPa)
Sensors/Transducers Type PRESSURE SENSOR,PEIZORESISTIVE
Housing CERAMIC
Max Pressure 60 PSI
Pressure Range-Max 15 Psi
REACH SVHC No SVHC
RoHS Status RoHS Compliant
Pricing & Ordering
Quantity Unit Price Ext. Price
250 $25.99852 $6499.63
SSCSNBN015PDAA5 Product Details

SSCSNBN015PDAA5 Overview


The 4-SIP, Dual Ports, Same Side package includes this transducer for convenience. In order to ensure reliable performance, the transducers should be set to -40°C~85°C. With a supply voltage of 4.75V~5.25V, the transducers can operate well. In order to make the transducers work properly, the 4 pins must be connected. This transducer has a maximum pressure range of 15 Psi. Normal operation of the transducers is possible with a nominal supply current of 2mA. For it to work, the transducers should release 4.5V voltage. To keep the transducers operating continuously at rated ambient temperatures, the DC voltage should be 5V. The current of the transducers should not exceed 3mA, otherwise it will be dangerous.

SSCSNBN015PDAA5 Features


Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: 4-SIP, Dual Ports, Same Side
Operating Temperature: -40°C~85°C
4 Pins
TruStability® SSC series
Operating Pressure: ±15PSI (±103.42kPa)
Operating Supply Voltage: 5V


SSCSNBN015PDAA5 Applications


There are a lot of Honeywell Sensing and Productivity Solutions
SSCSNBN015PDAA5 Transducers applications.


  • Process Control
  • Altitude Control of Drones and Flying Toys
  • Mobile Phones
  • Virtual Reality and Gaming Equipment
  • Indoor/Outdoor Navigation (dead-reckoning, floor/elevator/step detection)
  • Vertical velocity monitoring
  • Leisure, Sports, and Fitness Activity Identification
  • Weather Forecasting
  • Hydrogen Storage
  • Refrigerant pressure monitoring in HVAC/R systems