Welcome to Hotenda.com Online Store!

logo
userjoin
Home

S6006DTP

S6006DTP

S6006DTP

Littelfuse Inc.

SCR Standard Recovery -40°C~125°C 1.6V-On State (Vtm) (Max) 10μA-Current - Off State (Max) 2-Termination Tube TO-252-3, DPak (2 Leads + Tab), SC-63 Surface Mount

SOT-23

S6006DTP Datasheet

non-compliant

In-Stock: 0 items
Specifications
Name Value
Type Parameter
Factory Lead Time 18 Weeks
Mount Surface Mount
Mounting Type Surface Mount
Package / Case TO-252-3, DPak (2 Leads + Tab), SC-63
Operating Temperature -40°C~125°C
Packaging Tube
Published 2004
JESD-609 Code e3
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Number of Terminations 2
Terminal Finish Matte Tin (Sn)
HTS Code 8541.30.00.80
Voltage - Rated DC 600V
Terminal Position SINGLE
Terminal Form GULL WING
Peak Reflow Temperature (Cel) 260
Reach Compliance Code unknown
Current Rating 3.8A
Time@Peak Reflow Temperature-Max (s) 40
Pin Count 3
JESD-30 Code R-PSSO-G2
Qualification Status Not Qualified
Number of Elements 1
Configuration SINGLE
Case Connection ANODE
JEDEC-95 Code TO-252AA
RMS Current (Irms) 6A
Hold Current 30mA
Trigger Device Type SCR
Voltage - Off State 600V
Voltage - Gate Trigger (Vgt) (Max) 1.5V
Current - Non Rep. Surge 50, 60Hz (Itsm) 83A 100A
Current - Gate Trigger (Igt) (Max) 15mA
Current - Hold (Ih) (Max) 30mA
Leakage Current (Max) 0.5mA
SCR Type Standard Recovery
Voltage - On State (Vtm) (Max) 1.6V
Critical Rate of Rise of Off-State Voltage-Min 225V/us
Current - Off State (Max) 10μA
RMS On-state Current-Max 6A
RoHS Status ROHS3 Compliant
Lead Free Lead Free
Pricing & Ordering
Quantity Unit Price Ext. Price
750 $0.65693 $492.6975
S6006DTP Product Details

S6006DTP Overview


The RMS current is a measure of the average strength of the current, disregarding its direction. Its RMS current (Irms) is 6A ohms.In order for the device to operate normally, the RMS on-state current should be maintained at 6A.During the 'ON' state, the holding current (hypostatic) can be 30mA, as it is the minimum current which must pass through a circuit for it to stay in the 'on' state.Detecting leakage current on conductors can be an indication of insulation effectiveness, and its maximum leakage current can be 0.5mA.

S6006DTP Features


its RMS current (Irms) is 6A
its current can be 30mA
its maximal leakage current can be 0.5mA


S6006DTP Applications


There are a lot of Littelfuse Inc.
S6006DTP applications of SCRs thyristors.


  • DC motor control and drives
  • Battery charges
  • Welders
  • Power converters
  • Lighting control
  • Heat and temperature control
  • Motor starters
  • DC motor controls - AC motor controls
  • Uninterruptable power supplies
  • Wind mill

Related Part Number

Get Subscriber

Enter Your Email Address, Get the Latest News