DS600U+T&R datasheet pdf and Temperature Sensors - Analog and Digital Output product details from Maxim Integrated stock available on our website
SOT-23
DS600U+T&R Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
9 Weeks
Contact Plating
Tin
Mounting Type
Surface Mount
Package / Case
8-TSSOP, 8-MSOP (0.118, 3.00mm Width) Exposed Pad
Number of Pins
8
Supplier Device Package
8-uMax-EP
Operating Temperature
-40°C~125°C
Packaging
Tape & Reel (TR)
Published
2012
Feature
Shutdown Mode, Standby Mode
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Max Operating Temperature
125°C
Min Operating Temperature
-40°C
Voltage - Supply
2.7V~5.5V
Base Part Number
DS600
Output Type
Analog Voltage
Operating Supply Voltage
5.5V
Interface
Analog
Max Supply Voltage
5.5V
Min Supply Voltage
2.7V
Operating Supply Current
140μA
Resolution
6.45mV/°C
Sensor Type
Analog, Local
Test Condition
-20°C ~ 100°C (-40°C ~ 125°C)
Max Supply Voltage (DC)
5.5V
Min Supply Voltage (DC)
2.7V
Accuracy - Highest (Lowest)
±0.5°C (±0.75°C)
Sensing Temperature - Local
-40°C~125°C
Radiation Hardening
No
REACH SVHC
Unknown
RoHS Status
ROHS3 Compliant
Lead Free
Lead Free
DS600U+T&R Product Details
DS600U+T&R Overview
A safety precaution is taken by packaging these analog sensors in the Tape & Reel (TR). For protection against damage, analog sensors are enclosed in 8-TSSOP, 8-MSOP (0.118, 3.00mm Width) Exposed Pad packages. To operate properly, the sensor has pins 8. It is possible for the analog sensors to provide a current of 140μA when they are working. For a DC circuit, the maximum voltage supplied by this sensor should be 5.5V. However, the minimum voltage that this magnetic switch can supply in the DC circuit is 2.7V. When the analog sensors are operating, they would provide 5.5V voltage. It is possible to set the maximum operating temperature of the analog sensors to 125°C. It is important that the operating temperature of this sensor is not below -40°C to ensure its function.