PS60 Series Compound Pressure Sensor PNP - Open Collector -10°C~50°C -14.5PSI ~ 145.04PSI (-100kPa ~ 1000kPa) Threaded ±1% 12V~24V Temperature Compensated

SOT-23

PS60-103R-PMCN Datasheet

non-compliant

In-Stock: 0 items
Specifications
Name Value
Type Parameter
Factory Lead Time 9 Weeks
Package / Case Module Box with Display
Operating Temperature -10°C~50°C
Series PS60
Published 2008
Feature Temperature Compensated
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Termination Cable
Max Operating Temperature 50°C
Min Operating Temperature -10°C
Applications Industrial Automation
Voltage - Supply 12V~24V
Termination Style Cable
Output Type PNP - Open Collector
Accuracy ±1%
Operating Pressure -14.5PSI ~ 145.04PSI (-100kPa ~ 1000kPa)
Pressure Type Compound
Port Style Threaded
Port Size Female -M5
Maximum Pressure 600PSI (4136.85kPa)
Max Pressure 600 PSI
RoHS Status ROHS3 Compliant
Pricing & Ordering
Quantity Unit Price Ext. Price
3 $141.37333 $424.11999
5 $125.66400 $628.32
10 $117.81000 $1178.1
25 $113.88320 $2847.08
50 $109.95600 $5497.8
PS60-103R-PMCN Product Details

PS60-103R-PMCN Overview


This transducer was included in the Module Box with Display package for the convenience of the user. In order to ensure reliable operation, it is recommended that the transducers be set to -10°C~50°C. It has been found that the transducers are capable of operating at supply voltages of 12V~24V. A transducer can operate at 50°C. An operating temperature of lower than -10°C is not permitted for the transducers.

PS60-103R-PMCN Features


Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: Module Box with Display
Operating Temperature: -10°C~50°C
PS60 series
Operating Pressure: -14.5PSI ~ 145.04PSI (-100kPa ~ 1000kPa)


PS60-103R-PMCN Applications


There are a lot of Nidec Copal Electronics
PS60-103R-PMCN Transducers applications.


  • Weather Forecasting
  • Hydrogen Storage
  • Refrigerant pressure monitoring in HVAC/R systems
  • Dry air system pressure, process controls and automation
  • Dry air system monitoring
  • Hydraulic, brake, and engine oil fluid pressure monitoring
  • Air brake pressure monitoring
  • Vertical velocity indication (e.g. rise/sink speed)
  • Internet of things
  • Enhancement of GPS navigation