PS-A Series Compound Pressure Sensor Analog Voltage -10°C~60°C ±14.5PSI (±100kPa) Barbless ±1.25% 0 V ~ 4.5 V Amplified Output, Temperature Compensated
SOT-23
ADP5100 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
12 Weeks
Package / Case
6-DIP Module
Surface Mount
NO
Mounting Feature
THROUGH HOLE MOUNT
Number of Pins
6
Operating Temperature
-10°C~60°C
Series
PS-A
Published
2004
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PC Pin
Applications
Board Mount
Voltage - Rated DC
5V
Output
0 V ~ 4.5 V
Termination Style
PC Pin
Body Length or Diameter
7.2mm
Body Breadth
7 mm
Output Voltage
4.55V
Output Type
Analog Voltage
Nominal Supply Current
10mA
Accuracy
±1.25%
Operating Pressure
±14.5PSI (±100kPa)
Pressure Type
Compound
Port Style
Barbless
Port Size
Male - 0.12 3mm Tube
Maximum Pressure
±29.01PSI (±200kPa)
Sensors/Transducers Type
PRESSURE SENSOR,STRAIN GUAGE
Max Pressure
29.01 PSI
Pressure Range-Max
14.5 Psi
Pressure Sensing Mode
GAGE
Offset-Nom
2.50V
Body Height
3.5mm
REACH SVHC
No SVHC
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$42.69000
$42.69
5
$40.75400
$203.77
10
$36.87300
$368.73
25
$33.96200
$849.05
50
$30.08060
$1504.03
100
$29.11020
$2911.02
ADP5100 Product Details
ADP5100 Overview
This transducer is included in the 6-DIP Module package for your convenience. Transducers should have their temperature set to -10°C~60°C for reliable operation. The transducers can only function properly if the 6 pins are connected. Its maximum pressure range is 14.5 Psi. With nominal supply current of 10mA, the transducers will function normally. It should work with a voltage of 4.55V. It is important that the DC voltage be set to 5V to ensure that transducers are continuously capable of operating at the rated ambient temperature.