PS-A Series Vented Gauge Pressure Sensor Analog Voltage -10°C~60°C 14.5PSI (100kPa) Barbless ±1.25% 0 V ~ 4.5 V Amplified Output, Temperature Compensated
SOT-23
ADP5141 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
12 Weeks
Package / Case
6-DIP Module
Surface Mount
NO
Number of Pins
6
Operating Temperature
-10°C~60°C
Series
PS-A
Published
2004
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
Through Hole
Applications
Board Mount
Voltage - Rated DC
5V
Output
0 V ~ 4.5 V
Termination Style
PC Pin
Body Length or Diameter
7.2mm
Body Breadth
7 mm
Output Voltage
4.55V
Output Type
Analog Voltage
Nominal Supply Current
10mA
Accuracy
±1.25%
Operating Pressure
14.5PSI (100kPa)
Pressure Type
Vented Gauge
Port Style
Barbless
Port Size
Male - 0.12 3mm Tube
Maximum Pressure
29.01PSI (200kPa)
Sensors/Transducers Type
PRESSURE SENSOR,STRAIN GUAGE
Max Pressure
29.01 PSI
Pressure Range-Max
14.5 Psi
Pressure Sensing Mode
GAGE
Offset-Nom
0.5V
Body Height
3.5mm
REACH SVHC
No SVHC
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$42.69000
$42.69
5
$40.75400
$203.77
10
$36.87300
$368.73
25
$33.96200
$849.05
50
$30.08060
$1504.03
100
$29.11020
$2911.02
ADP5141 Product Details
ADP5141 Overview
As a convenience, the transducer is included in package 6-DIP Module. Reliable performance is ensured by setting the transducer temperature to -10°C~60°C. There is a requirement for connecting the 6 pins to make the transducer work properly. This transducer can handle pressures up to 14.5 Psi. Transducers working with 10mA supply current can function normally. In order for it to work, the voltage released by the transducers must be 4.55V. For the transducers to continuously work at the rated ambient temperature, DC voltage should be 5V.