Panasonic Electronic Components

PS-A Series Vented Gauge Pressure Sensor Analog Voltage -5°C~50°C 5.8PSI (40kPa) Barbless ±4% 0.3 V ~ 2.7 V 3V Amplified Output, Temperature Compensated

SOT-23

ADP51A11 Datasheet

non-compliant

In-Stock: 0 items
Specifications
Name Value
Type Parameter
Factory Lead Time 12 Weeks
Mount PCB, Through Hole
Package / Case 8-DIP Module
Number of Pins 6
Operating Temperature -5°C~50°C
Series PS-A
Published 2008
Feature Amplified Output, Temperature Compensated
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Termination PC Pin
Applications Board Mount
Voltage - Rated DC 5V
Voltage - Supply 3V
Output 0.3 V ~ 2.7 V
Termination Style PC Pin
Body Length or Diameter 7.2mm
Body Breadth 7 mm
Output Voltage 4.5V
Output Type Analog Voltage
Operating Supply Voltage 5V
Nominal Supply Current 3mA
Accuracy ±4%
Operating Pressure 5.8PSI (40kPa)
Pressure Type Vented Gauge
Port Style Barbless
Port Size Male - 0.12 3mm Tube
Maximum Pressure 11.6PSI (80kPa)
Sensors/Transducers Type PRESSURE SENSOR,STRAIN GUAGE
Max Pressure 11.6 PSI
Pressure Range-Max 5.8 Psi
Pressure Sensing Mode GAGE
Offset-Nom 0.3V
Body Height 3.5mm
REACH SVHC No SVHC
RoHS Status RoHS Compliant
Pricing & Ordering
Quantity Unit Price Ext. Price
1 $17.85000 $17.85
5 $17.48800 $87.44
10 $14.57400 $145.74
25 $13.48080 $337.02
50 $13.11660 $655.83
100 $11.29490 $1129.49
500 $10.56616 $5283.08
ADP51A11 Product Details

ADP51A11 Overview


For convenience, this transducer is included in the 8-DIP Module package. The temperature of the transducers should be set to -5°C~50°C to ensure reliable performance. The transducers can operate well with a supply voltage of 3V. For the transducers to work properly, 6 pins must be connected in order to make it work. The maximum pressure range set by this transducer is 5.8 Psi. The transducers can have a normal operation with nominal supply current of 3mA. The voltage released by the transducers should be 4.5V to make it work. DC voltage should be 5V so that the transducers can continuously operate at the rated ambient temperature.

ADP51A11 Features


Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: 8-DIP Module
Operating Temperature: -5°C~50°C
6 Pins
PS-A series
Operating Pressure: 5.8PSI (40kPa)
Operating Supply Voltage: 5V


ADP51A11 Applications


There are a lot of Panasonic Electronic Components
ADP51A11 Transducers applications.


  • General Purpose
  • Process Control
  • Altitude Control of Drones and Flying Toys
  • Mobile Phones
  • Virtual Reality and Gaming Equipment
  • Indoor/Outdoor Navigation (dead-reckoning, floor/elevator/step detection)
  • Vertical velocity monitoring
  • Leisure, Sports, and Fitness Activity Identification
  • Weather Forecasting