PS-A Series Compound Pressure Sensor Analog Voltage -10°C~60°C ±14.5PSI (±100kPa) Barbless ±1.25% 0 V ~ 4.5 V 5V Amplified Output, Temperature Compensated
SOT-23
ADP5200 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
12 Weeks
Package / Case
6-SMD Module
Surface Mount
YES
Mounting Feature
SURFACE MOUNT
Number of Pins
6
Operating Temperature
-10°C~60°C
Series
PS-A
Published
2004
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
Gull Wing
Applications
Board Mount
Voltage - Supply
5V
Output
0 V ~ 4.5 V
Termination Style
Gull Wing
Body Length or Diameter
7mm
Body Breadth
7.2 mm
Output Voltage
4.55V
Output Type
Analog Voltage
Accuracy
±1.25%
Operating Pressure
±14.5PSI (±100kPa)
Pressure Type
Compound
Port Style
Barbless
Port Size
Male - 0.12 3mm Tube
Maximum Pressure
±29.01PSI (±200kPa)
Sensors/Transducers Type
PRESSURE SENSOR,STRAIN GUAGE
Max Pressure
29.01 PSI
Pressure Range-Max
14.5 Psi
Pressure Sensing Mode
GAGE
Offset-Nom
0.50V
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$46.080000
$46.08
10
$43.471698
$434.71698
100
$41.011036
$4101.1036
500
$38.689657
$19344.8285
1000
$36.499676
$36499.676
ADP5200 Product Details
ADP5200 Overview
In order to make your life easier, a 6-SMD Module package includes this transducer. If you want reliable results, you should set the transducers' temperature to -10°C~60°C. Supply voltages as low as 5V work well with the transducers. 6 pins must be connected in order for the transducer to work properly. A transducer of this type is capable of measuring pressures up to 14.5 Psi. If it is to work, the transducers' voltage should be 4.55V.