DPH-L100 Series Compound Pressure Sensor Analog Voltage -20°C~70°C ±145.04PSI (±1000kPa) Threaded ±2% 1 V ~ 5 V 9V~36V
SOT-23
DPH-L113V Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
8 Weeks
Package / Case
Cylinder, Threaded
Operating Temperature
-20°C~70°C
Series
DPH-L100
Part Status
Obsolete
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
Connector
Max Operating Temperature
70°C
Min Operating Temperature
-20°C
Applications
Industrial Automation
Voltage - Supply
9V~36V
Output
1 V ~ 5 V
Termination Style
Connector
Output Type
Analog Voltage
Accuracy
±2%
Operating Pressure
±145.04PSI (±1000kPa)
Pressure Type
Compound
Port Style
Threaded
Port Size
Male - 1/4 6.35mm BSPT
Maximum Pressure
±290.08PSI (±2000kPa)
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$298.00000
$298
500
$295.02
$147510
1000
$292.04
$292040
1500
$289.06
$433590
2000
$286.08
$572160
2500
$283.1
$707750
DPH-L113V Product Details
DPH-L113V Overview
Cylinder, Threaded includes this transducer for convenience. Reliable performance can be assured by setting the transducers to -20°C~70°C. A supply voltage of 9V~36V is sufficient for the transducers to operate well. It is possible to reach the maximum operating temperature of the transducers 70°C. Temperatures of the transducers cannot be below -20°C.