MediaSensor™ Series Sealed Gauge Pressure Sensor Analog Voltage -40°C~105°C 100PSI (689.48kPa) Threaded ±0.5% 0.5 V ~ 4.5 V 5V Amplified Output, Temperature Compensated
SOT-23
P51-100-S-P-M12-4.5OVP-000-000 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
7 Weeks
Package / Case
Cylinder
Operating Temperature
-40°C~105°C
Series
MediaSensor™
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Max Operating Temperature
105°C
Min Operating Temperature
-40°C
Applications
Industrial Automation
Voltage - Supply
5V
Output
0.5 V ~ 4.5 V
Termination Style
M12, 4 Pin
Output Type
Analog Voltage
Accuracy
±0.5%
Operating Pressure
100PSI (689.48kPa)
Pressure Type
Sealed Gauge
Port Style
Threaded
Port Size
Male -M20 x 1.5
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
5
$149.18400
$745.92
P51-100-S-P-M12-4.5OVP-000-000 Product Details
P51-100-S-P-M12-4.5OVP-000-000 Overview
In order to make your life easier, a Cylinder package includes this transducer. If you want reliable results, you should set the transducers' temperature to -40°C~105°C. Supply voltages as low as 5V work well with the transducers. Temperatures of 105°C are the maximum operating temperatures of the transducers. It is impossible to operate the transducers below -40°C.