MediaSensor™ Series Sealed Gauge Pressure Sensor Analog Current -40°C~105°C 500PSI (3447.38kPa) Threaded ±0.5% 4 mA ~ 20 mA 8V~30V Amplified Output, Temperature Compensated
SOT-23
P51-500-S-B-I36-20MA-000-000 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
7 Weeks
Package / Case
Cylinder
Operating Temperature
-40°C~105°C
Series
MediaSensor™
Published
2016
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
Cable
Max Operating Temperature
105°C
Min Operating Temperature
-40°C
Applications
Industrial Automation
Voltage - Rated DC
30V
Voltage - Supply
8V~30V
Output
4 mA ~ 20 mA
Termination Style
Cable 3'
Output Type
Analog Current
Accuracy
±0.5%
Operating Pressure
500PSI (3447.38kPa)
Pressure Type
Sealed Gauge
Port Style
Threaded
Port Size
Male - 1/8 3.18mm NPT
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
10
$85.64800
$856.48
P51-500-S-B-I36-20MA-000-000 Product Details
P51-500-S-B-I36-20MA-000-000 Overview
The Transducer Cylinder is included in the package for convenience. It is recommended to set the temperature of the transducers to -40°C~105°C to ensure reliable operation. The transducers are capable of operating well at 8V~30V supply voltage. 105°C is the maximum operating temperature of the transducers. It is not possible for the transducers to operate at temperatures lower than -40°C. In order to keep the transducers at the temperature they are rated for, the DC voltage needs to be 30V.