MSP300 Series Vented Gauge Pressure Sensor Analog Voltage -20°C~85°C 1000PSI (6894.76kPa) Threaded ±1% 1 V ~ 5 V 10V~30V Amplified Output, Temperature Compensated
SOT-23
M3041-000006-01KPG Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Lifecycle Status
ACTIVE (Last Updated: 4 days ago)
Factory Lead Time
16 Weeks
Mount
Stud
Package / Case
Cylinder, Threaded
Operating Temperature
-20°C~85°C
Series
MSP300
Published
2006
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
Cable
Max Operating Temperature
85°C
Min Operating Temperature
-20°C
Applications
Industrial Automation
Voltage - Rated DC
30V
Voltage - Supply
10V~30V
Output
1 V ~ 5 V
Termination Style
Cable
Output Voltage
5V
Output Type
Analog Voltage
Accuracy
±1%
Operating Pressure
1000PSI (6894.76kPa)
Pressure Type
Vented Gauge
Port Style
Threaded
Port Size
Male - 1/8 3.18mm NPT
Maximum Pressure
2000PSI (13789.51kPa)
Radiation Hardening
No
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$75.20000
$75.2
5
$71.44000
$357.2
10
$65.80000
$658
25
$58.28000
$1457
50
$56.40000
$2820
100
$54.52000
$5452
M3041-000006-01KPG Product Details
M3041-000006-01KPG Overview
For convenience, this transducer is included in the Cylinder, Threaded package. The temperature of the transducers should be set to -20°C~85°C to ensure reliable performance. The transducers can operate well with a supply voltage of 10V~30V. The maximum operating temperature of the transducers can be reached 85°C. The operating temperature of the transducers cannot be lower than -20°C. The voltage released by the transducers should be 5V to make it work. DC voltage should be 30V so that the transducers can continuously operate at the rated ambient temperature.