200μA per Channel 100pA 55 dB Instrumentational OP Amps 6V 2.5V~12V ±1.25V~6V TLV2244 14 Pins 14-DIP (0.300, 7.62mm)
SOT-23
TLV2244IN Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
8 Weeks
Lifecycle Status
ACTIVE (Last Updated: 5 days ago)
Mounting Type
Through Hole
Package / Case
14-DIP (0.300, 7.62mm)
Surface Mount
NO
Number of Pins
14
Operating Temperature
-40°C~85°C
Packaging
Tube
JESD-609 Code
e4
Pbfree Code
yes
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Number of Terminations
14
ECCN Code
EAR99
Terminal Finish
Nickel/Palladium/Gold (Ni/Pd/Au)
Subcategory
Operational Amplifier
Technology
BIPOLAR
Terminal Position
DUAL
Number of Functions
4
Supply Voltage
2.7V
Base Part Number
TLV2244
Pin Count
14
Output Type
Rail-to-Rail
Operating Supply Voltage
6V
Number of Elements
4
Power Supplies
+-1.25/+-6/2.5/12V
Operating Supply Current
1μA
Nominal Supply Current
5μA
Power Dissipation
1.6W
Output Current
200μA
Slew Rate
0.002V/μs
Architecture
VOLTAGE-FEEDBACK
Amplifier Type
General Purpose
Common Mode Rejection Ratio
55 dB
Current - Input Bias
100pA
Voltage - Supply, Single/Dual (±)
2.5V~12V ±1.25V~6V
Output Current per Channel
200μA
Input Offset Voltage (Vos)
3mV
Bandwidth
5.5 kHz
Unity Gain BW-Nom
5.5 kHz
Voltage Gain
120dB
Power Supply Rejection Ratio (PSRR)
70dB
Low-Offset
NO
Frequency Compensation
YES
Supply Voltage Limit-Max
16.5V
Voltage - Input Offset
600μV
Low-Bias
YES
Micropower
YES
Programmable Power
NO
Max I/O Voltage
3mV
Height
5.08mm
Length
19.3mm
Width
6.35mm
Thickness
3.9mm
Radiation Hardening
No
RoHS Status
ROHS3 Compliant
Lead Free
Lead Free
Pricing & Ordering
Quantity
Unit Price
Ext. Price
200
$2.52330
$504.66
TLV2244IN Product Details
TLV2244IN Overview
There is a 14-DIP (0.300, 7.62mm) case package that contains the instrumentation amplifiers. A General Purpose-type buffer amplifier is shown here. It comes in a Tube case, which protects instrumentation amplifier from damage during delivery. We are approaching the 14h termination of the year. In this case, there are 14 pins on the board. As a reminder, this buffer op amp should be powered by 2.7V battery and that the battery should be inserted in the amplifier. Instrumentation amplifier is a part of Operational Amplifier. 14 pins are available on the instrumentation amplifier. With regard to input offset voltage, instrumentation amplifier is rated at 3mV. This electronic part is best mounted with type Through Hole. With regard to operating temperature, op amp ranges -40°C~85°C. Using a supply current of 1μA , this buffer op amp will be able to operate. You should keep the voltage gain at 120dB for the time being. There are more than a few advantages to using this instrumentation amplifier, one of which is that it outputs Rail-to-Rail signals. There is a rating of 4 for the operating supply voltage of the buffer op amp. The operating supply voltage of instrumentation amplifier is rated 6V voltage.
TLV2244IN Features
14 Pins supply voltage of 2.7V 120dB voltage gain Output Type: Rail-to-Rail
TLV2244IN Applications
There are a lot of Texas Instruments TLV2244IN Instrumentational OP Amps applications.