SCR Standard Recovery -40°C~110°C 1.7V-On State (Vtm) (Max) 2mA-Current - Off State (Max) Tube TO-220-3 Through Hole
SOT-23
TIC116S-S Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Mount
Through Hole
Mounting Type
Through Hole
Package / Case
TO-220-3
Operating Temperature
-40°C~110°C
Packaging
Tube
Published
1993
Part Status
Obsolete
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Base Part Number
TIC116
Max Repetitive Reverse Voltage (Vrrm)
700V
RMS Current (Irms)
8A
Hold Current
40mA
Trigger Device Type
SCR
Voltage - Off State
700V
Voltage - Gate Trigger (Vgt) (Max)
1.5V
Current - Non Rep. Surge 50, 60Hz (Itsm)
80A @ 50Hz
Current - Gate Trigger (Igt) (Max)
20mA
Leakage Current (Max)
2mA
Current - On State (It (AV)) (Max)
5A
Non-Repetitive Pk On-state Cur
80 A
SCR Type
Standard Recovery
Voltage - On State (Vtm) (Max)
1.7V
Current - Off State (Max)
2mA
Radiation Hardening
No
RoHS Status
ROHS3 Compliant
TIC116S-S Product Details
TIC116S-S Overview
Despite its direction, the RMS current (Irms) describes the average strength of the current.Its maximal repetitive reverse voltage (Vrrm) is 700V, meaning it can withstand the maximum amount of voltage in reverse-bias mode.Holding current (hypostatic) for electrical, electromagnetic, and electronic devices is the minimum current passing through a circuit in order for it to remain in an "ON" state.Insulation effectiveness can be measured by leakage current, with a maximal leakage current of 2mA.
TIC116S-S Features
its RMS current (Irms) is 8A its current can be 40mA its maximal leakage current can be 2mA
TIC116S-S Applications
There are a lot of Bourns Inc. TIC116S-S applications of SCRs thyristors.