CSLA Series Hall Effect, Open Loop Sensor 1-Channel Bidirectional -25°C~85°C 6V~12V 550A
SOT-23
CSLA2EL Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
13 Weeks
Mount
PCB
Mounting Type
Through Hole
Package / Case
Module, Single Pass Through
Number of Pins
3
Housing Material
PBT
Operating Temperature
-25°C~85°C
Packaging
Bulk
Series
CSLA
Published
1998
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Max Operating Temperature
85°C
Min Operating Temperature
-25°C
Voltage - Supply
6V~12V
Current Rating
550A
Output
Ratiometric, Voltage
Current - Supply (Max)
20mA
Output Type
Voltage
Polarity
Bidirectional
Number of Channels
1
Max Supply Voltage
12V
Min Supply Voltage
6V
Polarization
Bidirectional
Nominal Supply Current
20mA
Max Supply Current
20mA
Response Time
3μs
Sensor Type
Hall Effect, Open Loop
Sensitivity
4.3mV/N
Max Supply Voltage (DC)
12V
Min Supply Voltage (DC)
6V
For Measuring
AC/DC
Current - Sensing
550A
Length
63.5mm
REACH SVHC
Unknown
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$55.06000
$55.06
5
$52.30800
$261.54
10
$48.17800
$481.78
25
$42.67160
$1066.79
50
$41.29500
$2064.75
100
$39.91850
$3991.85
CSLA2EL Product Details
CSLA2EL Overview
Current sensors are packaged in Module, Single Pass Through packages to ensure their safety. Current sensors are packaged in the Bulk for protection. Ideally, these current sensors should supply a maximum current of 20mA. Current sensors should not supply current higher than 20mA. It is imperative that these current sensors be operated at temperatures not below -25°C. As a result, the maximum operating temperature should be set to 85°C for the current sensors. It has been designed for 550A current to be sensed by the current sensors. As far as this current sensor is concerned, there are only 3 pins. Accordingly, the current provided by current sensors should have a nominal value of 20mA. This sensors should supply a voltage not less than 6V in a DC circuit. In the DC circuit, the voltage supplied by the current sensors should however not exceed 12V.
CSLA2EL Features
Moisture Sensitivity Level: 1 (Unlimited) Operating Temperature: -25°C~85°C 1 Channels Mounting Type: Through Hole Sensor Type: Hall Effect, Open Loop Supply Voltage: 6V~12V Sensing Current: 550A Module, Single Pass Through Package
CSLA2EL Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA2EL Current Sensors applications.