TruStability® HSC Series Vented Gauge Pressure Sensor SPI -20°C~85°C 60PSI (413.69kPa) Barbed ±0.25% 12 b 3V~3.6V Amplified Output, Temperature Compensated
SOT-23
HSCDANN060PGSA3 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
13 Weeks
Package / Case
8-DIP (0.524, 13.30mm), Top Port
Surface Mount
NO
Mounting Feature
THROUGH HOLE MOUNT
Number of Pins
8
Operating Temperature
-20°C~85°C
Series
TruStability® HSC
Published
2011
Feature
Amplified Output, Temperature Compensated
Pbfree Code
yes
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Applications
Board Mount
Voltage - Supply
3V~3.6V
Reach Compliance Code
unknown
Output
12 b
Termination Style
PC Pin
Body Length or Diameter
12.45mm
Body Breadth
9.91 mm
Output Type
SPI
Operating Supply Voltage
3.3V
Nominal Supply Current
1.6mA
Number of Bits
12
Accuracy
±0.25%
Response Time
460 μs
Operating Pressure
60PSI (413.69kPa)
Pressure Type
Vented Gauge
Port Style
Barbed
Port Size
Male - 0.19 4.93mm Tube
Maximum Pressure
120PSI (827.37kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
CERAMIC
Pressure Range-Max
60 Psi
Pressure Sensing Mode
GAGE
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$87.310000
$87.31
10
$82.367925
$823.67925
100
$77.705589
$7770.5589
500
$73.307160
$36653.58
1000
$69.157698
$69157.698
HSCDANN060PGSA3 Product Details
HSCDANN060PGSA3 Overview
As a convenience, this transducer is included in 8-DIP (0.524, 13.30mm), Top Port. Temperature should be set at -20°C~85°C on transducers in order for them to work reliably. Obtaining a 3V~3.6V supply voltage is not a problem for the transducers. To ensure proper operation of the transducers, it is necessary to connect the 8 pins. There is a maximum pressure range of 60 Psi set by this transducer. A nominal supply current of 1.6mA can run the transducers normally.
HSCDANN060PGSA3 Features
Moisture Sensitivity Level: 1 (Unlimited) Package / Case: 8-DIP (0.524, 13.30mm), Top Port Operating Temperature: -20°C~85°C 8 Pins TruStability® HSC series Operating Pressure: 60PSI (413.69kPa) Operating Supply Voltage: 3.3V
HSCDANN060PGSA3 Applications
There are a lot of Honeywell Sensing and Productivity Solutions HSCDANN060PGSA3 Transducers applications.
Hydrogen Storage
Refrigerant pressure monitoring in HVAC/R systems
Dry air system pressure, process controls and automation
Dry air system monitoring
Hydraulic, brake, and engine oil fluid pressure monitoring