TBP Series Vented Gauge Pressure Sensor Wheatstone Bridge -40°C~125°C 60PSI (413.69kPa) Barbless ±0.15% 0 mV ~ 6.5 mV (5V) 1.5V~12V Temperature Compensated

SOT-23

TBPMLNN060PGUCV Datasheet

non-compliant

In-Stock: 0 items
Specifications
Name Value
Type Parameter
Factory Lead Time 9 Weeks
Package / Case 6-SMD, No Lead, Top Port
Surface Mount YES
Mounting Feature SURFACE MOUNT
Number of Pins 4
Operating Temperature -40°C~125°C
Series TBP
Published 2014
Feature Temperature Compensated
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Termination SMD/SMT
Applications Board Mount
Additional Feature IT HAS ACCURACY 0.15 PERCENTAGE
Voltage - Rated DC 5V
Voltage - Supply 1.5V~12V
Output 0 mV ~ 6.5 mV (5V)
Termination Style SMD (SMT) Tab
Output Type Wheatstone Bridge
Operating Supply Voltage 5V
Nominal Supply Current 600μA
Max Supply Current 1mA
Accuracy ±0.15%
Operating Pressure 60PSI (413.69kPa)
Pressure Type Vented Gauge
Port Style Barbless
Port Size Male - 0.13 3.18mm Tube
Maximum Pressure 145PSI (999.74kPa)
Sensors/Transducers Type PRESSURE SENSOR,PEIZORESISTIVE
Pressure Range-Max 60 Psi
Pressure Sensing Mode GAGE
REACH SVHC Unknown
RoHS Status RoHS Compliant
Pricing & Ordering
Quantity Unit Price Ext. Price
1 $12.50000 $12.5
5 $10.96200 $54.81
10 $9.86500 $98.65
25 $8.76920 $219.23
50 $8.11140 $405.57
250 $6.79596 $1698.99
500 $6.57676 $3288.38
1,000 $6.13830 $6.1383
TBPMLNN060PGUCV Product Details

TBPMLNN060PGUCV Overview


This transducer is included in the package 6-SMD, No Lead, Top Port for your convenience. For reliable performance, the transducers should be set to -40°C~125°C. The transducers are capable of operating with a supply voltage of 1.5V~12V. There is a requirement that 4 pins be connected for the transducers to function properly. A transducer of this type can measure pressures up to 60 Psi. When the supply current is set to 600μA, the transducers will operate normally. For the transducers to operate continuously at ambient temperatures, the DC voltage should be set to 5V. The current of the transducers should not exceed 1mA, otherwise it will be dangerous.

TBPMLNN060PGUCV Features


Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: 6-SMD, No Lead, Top Port
Operating Temperature: -40°C~125°C
4 Pins
TBP series
Operating Pressure: 60PSI (413.69kPa)
Operating Supply Voltage: 5V


TBPMLNN060PGUCV Applications


There are a lot of Honeywell Sensing and Productivity Solutions
TBPMLNN060PGUCV Transducers applications.


  • Mobile Phones
  • Virtual Reality and Gaming Equipment
  • Indoor/Outdoor Navigation (dead-reckoning, floor/elevator/step detection)
  • Vertical velocity monitoring
  • Leisure, Sports, and Fitness Activity Identification
  • Weather Forecasting
  • Hydrogen Storage
  • Refrigerant pressure monitoring in HVAC/R systems
  • Dry air system pressure, process controls and automation
  • Dry air system monitoring

Related Part Number