CSLA1CD datasheet pdf and Current Sensors product details from Honeywell Sensing and Productivity Solutions stock available on our website
SOT-23
CSLA1CD Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
8 Weeks
Mount
PCB
Mounting Type
Through Hole
Package / Case
Module, Single Pass Through
Number of Pins
3
Housing Material
PBT
Operating Temperature
-25°C~85°C
Packaging
Bulk
Published
1998
Series
CSLA
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
Connector
Max Operating Temperature
85°C
Min Operating Temperature
-25°C
Voltage - Supply
8V~16V
Current Rating
19mA
Output
Ratiometric, Voltage
Current - Supply (Max)
19mA
Output Type
Voltage
Polarity
Bidirectional
Number of Channels
1
Max Supply Voltage
16V
Min Supply Voltage
8V
Polarization
Bidirectional
Nominal Supply Current
19mA
Max Supply Current
19mA
Max Voltage Rating (DC)
16V
Response Time
3μs
Wire/Cable Diameter
10.9 mm
Sensor Type
Hall Effect, Open Loop
Sensing Method
Inductive
Sensitivity
49.6mV/N
Max Supply Voltage (DC)
16V
Min Supply Voltage (DC)
8V
For Measuring
AC/DC
Current - Sensing
57A
Height
35.56mm
Length
34.3mm
Width
10.414mm
REACH SVHC
Unknown
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$29.22000
$29.22
5
$27.88800
$139.44
10
$25.23200
$252.32
25
$23.24000
$581
50
$20.58400
$1029.2
100
$19.92000
$1992
500
$18.59200
$9296
CSLA1CD Product Details
CSLA1CD Overview
As a safety precaution, the current sensors are packaged in Module, Single Pass Through packages. The devices are protected from damage by the Bulk package. The maximum current supplied by these current sensors should be 19mA. There should be no current greater than 19mA coming from current sensors. Ensure that the operating temperature of the current sensor is not lower than -25°C. The current sensors should remain at 85°C for the maximum operating temperature. Current sensors have been designed to measure current at 19mA. This current sensor consists of 3 pins. As a rule of thumb, current sensors should supply 19mA current. The voltage supplied by these sensors cannot fall below 8V in a DC circuit. In the DC circuit, the voltage provided by the current sensors should not exceed 16V.
CSLA1CD Features
Moisture Sensitivity Level: 1 (Unlimited) Operating Temperature: -25°C~85°C 1 Channels Mounting Type: Through Hole Sensor Type: Hall Effect, Open Loop Supply Voltage: 8V~16V Sensing Current: 57A Module, Single Pass Through Package
CSLA1CD Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA1CD Current Sensors applications.