TruStability® SSC Series Vented Gauge Pressure Sensor Analog Voltage -40°C~85°C 15PSI (103.42kPa) Barbed ±0.25% 0.5 V ~ 4.5 V 4.75V~5.25V Amplified Output, Temperature Compensated
SOT-23
SSCDANN015PGAA5 Datasheet
non-compliant
In-Stock: 0 items
Specifications
Name
Value
Type
Parameter
Factory Lead Time
11 Weeks
Mount
Through Hole
Package / Case
8-DIP (0.524, 13.30mm), Top Port
Number of Pins
8
Operating Temperature
-40°C~85°C
Series
TruStability® SSC
Published
2011
Feature
Amplified Output, Temperature Compensated
Part Status
Active
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Termination
PCB
Applications
Board Mount
Voltage - Rated DC
5V
Voltage - Supply
4.75V~5.25V
Output
0.5 V ~ 4.5 V
Termination Style
PC Pin
Output Voltage
4.5V
Output Type
Analog Voltage
Operating Supply Voltage
5V
Nominal Supply Current
2mA
Max Supply Current
3mA
Accuracy
±0.25%
Response Time
1 ms
Operating Pressure
15PSI (103.42kPa)
Pressure Type
Vented Gauge
Port Style
Barbed
Port Size
Male - 0.19 4.93mm Tube
Maximum Pressure
30PSI (206.84kPa)
Sensors/Transducers Type
PRESSURE SENSOR,PEIZORESISTIVE
Housing
CERAMIC
Max Pressure
30 PSI
Pressure Range-Max
15 Psi
Pressure Sensing Mode
GAGE
RoHS Status
RoHS Compliant
Pricing & Ordering
Quantity
Unit Price
Ext. Price
1
$36.04000
$36.04
5
$34.39800
$171.99
10
$31.12200
$311.22
25
$28.66520
$716.63
50
$25.38900
$1269.45
100
$24.57000
$2457
SSCDANN015PGAA5 Product Details
SSCDANN015PGAA5 Overview
The Transducer 8-DIP (0.524, 13.30mm), Top Port is included in the package for convenience. It is recommended to set the temperature of the transducers to -40°C~85°C to ensure reliable operation. The transducers are capable of operating well at 4.75V~5.25V supply voltage. In order for the transducers to function properly, the 8 pins must be connected. This transducer can handle pressures up to 15 Psi. If the nominal supply current is 2mA, the transducers will operate normally. This device must work at 4.5V voltage from the transducers. In order to keep the transducers at the temperature they are rated for, the DC voltage needs to be 5V. The current of the transducers should not exceed 3mA, otherwise it will be dangerous.
SSCDANN015PGAA5 Features
Moisture Sensitivity Level: 1 (Unlimited) Package / Case: 8-DIP (0.524, 13.30mm), Top Port Operating Temperature: -40°C~85°C 8 Pins TruStability® SSC series Operating Pressure: 15PSI (103.42kPa) Operating Supply Voltage: 5V
SSCDANN015PGAA5 Applications
There are a lot of Honeywell Sensing and Productivity Solutions SSCDANN015PGAA5 Transducers applications.
Weather Forecasting
Hydrogen Storage
Refrigerant pressure monitoring in HVAC/R systems
Dry air system pressure, process controls and automation
Dry air system monitoring
Hydraulic, brake, and engine oil fluid pressure monitoring