An op amp's input capacitance is defined as the capacitance between both of its input terminals with either input grounded, and 7015pF @ 25V is its maximum input capacitance.The drain current is the maximum continuous current the device can conduct, and this device has 47A continuous drain current (ID).Input capacitance must be charged before drain current conduction can begin, so the turn-off delay time is 110 ns.Before drain current conduction begins, the device's input capacitance must be charged, so the delay time is 18 ns.An FET transistor's gate-source voltage, VGS, indicates how much voltage is applied across the transistor's gate-source terminal and it can range from 20V to 1.For this transistor to work, a voltage 600V is required between drain and source (Vdss).Using drive voltage (10V), this device contributes to a reduction in overall power consumption.
APT47N60SC3G Features
a continuous drain current (ID) of 47A the turn-off delay time is 110 ns a 600V drain to source voltage (Vdss)
APT47N60SC3G Applications
There are a lot of Microsemi Corporation APT47N60SC3G applications of single MOSFETs transistors.
AC-DC Power Supply
Synchronous Rectification for ATX 1 Server I Telecom PSU